4.3 Determining the Installation Position
Basic Requirements
The SUN2000 is protected to IP65 and can be installed indoors or outdoors.
Do not install the SUN2000 in a place where personnel are easy to come into
contact with its enclosure and heat sink, because these parts are extremely
hot during operation.
Do not install the SUN2000 near
ammable or explosive materials.
Do not install the SUN2000 at a place within children's reach.
The SUN2000 will be corroded in salt areas, and the salt corrosion may cause
re. Do not install the SUN2000 outdoors in salt areas. A salt area refers to
the region within 500 meters from the coast or prone to sea breeze. The
SUN2000-(2KTL-6KTL)-L1
User Manual 4 System Installation