Category Status Description
Blinking red at short
intervals (on for 0.2s
and then o for 0.2s)
There is an AC
environmental alarm,
such as an alarm
indicating Grid
Undervoltage, Grid
Overvoltage, Grid
Overfrequency, or Grid
Underfrequency.
Steady red Steady red Fault.
Communication
indicator
LED3
Blinking green at short intervals (on for 0.2s and
then o for 0.2s)
Communication is in
progress.
Blinking green at long intervals (on for 1s and
then o for 1s)
The mobile phone is
connected to the
SUN2000.
O There is no
communication.
NO TE
If the o-grid load is overloaded, indicators LED1 and LED2 on the inverter blink orange
slowly. Reduce the
o-grid load power and manually clear the alarm or until the inverter is
recovered. The inverter attempts to restart at an interval of 5 minutes. If the inverter fails to
restart for three times, the interval changes to 2 hours. If the inverter is standby in o-grid
mode, check the inverter alarms and rectify the fault.
Table 6-3 LED indicators 2
Category
Status Description
Device
replacement
indication
LED1 LED2 LED3
Steady red Steady red Steady red The SUN2000 hardware
is faulty. The SUN2000
needs to be replaced.
----End
SUN2000-(2KTL-6KTL)-L1
User Manual 6 System Commissioning
Issue 10 (2023-02-13) Copyright © Huawei Technologies Co., Ltd. 68