SR05-D1A3-PV manual v1801 45/83
6.3 Silicon Reference Cell compatible Modbus output
SR05-D1A3-PV has an IMT-Solar Si-RS485TC-T-MB silicon reference cell compatible
Modbus output. The corresponding input registers, diagnostic function and serial
communication settings are explained below.
6.3.1 Input registers (0x04)
Table 6.3.1.1 PV reference cell compatible input registers.
MODBUS REGISTERS 0x0000-0x0008
REGISTER
ADDRESS
(HEX)
PARAMETER DESCRIPTION OF CONTENT TYPE
OF
(R/W)
FORMAT
OF
DATA
0x0000 Irradiance (W/m
) Irradiance = value/10 R U16
Temperature = (value-250)/10
0x0002 External temperature
(
°
C)
Not available, always returns 0 R U16
0x0003 Wind speed (m/s) Not available, always returns 0 R U16
0x0004 Factory use only - - -
0x0005 Cell temperature (
C) Temperature = (value-1000)/10 R U16
Not available, always returns 0
0x0007 Cell temperature (
C) Temperature = value/10 R S16
Not available, always returns 0
6.3.2 Diagnostics (0x08)
Diagnostic subfunction codes supported by SR05-D1A3-PV are listed in Table 6.3.2.1
Table 6.3.2.1 Diagnostic subfunction codes supported by SR05-D1A3-PV
DIAGNOSTIC SUBFUNCTION CODES
SUB
FUNCTION
0x0001 Restart communications
0x000B Bus message count 0x0000 Only counts messages for this
Not available, always returns 0
Not available, always returns 0
Not available, always returns 0