EasyManua.ls Logo

Hunter 50 - Water Heater Operation and Adjustment

Hunter 50
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hu
nt
e
r
50
• Water S
y
stems
9
.
6
‘o’ rin
g
that is the seal on the cap. Check for wear, or
leaka
g
e. Replace if needed
(
Contact
y
our dealer for
replacement
)
.
WARNING
! !
Hot coolant under pressure ma
y
boil or explode and
c
ause
b
urns or ot
h
er persona
l
i
n
j
ur
y
w
h
en t
h
e pres-
sure cap is removed. Allow the en
g
ine to cool, then
open the cap slowl
y
to allow an
y
pressure to vent
before completel
y
removin
g
the cap.
CAUTION
! !
Before usin
g
an
y
s
y
stem that requires raw coolin
g
water, ensure that the intake valve is o
p
ened and the
strainers are not clo
gg
ed. Section 9.4.6 illustrates
the procedure for cleanin
g
y
our strainers
.
9
.4.6 Water Heater
The
f
resh water pump supplies water to the water heater
from the water tanks. A breaker on the AC side of the
M
DP, and a rocker switch on the control panel controls
power to the heater.
Follow these procedures when usin
g
the water heater
:
1. Make sure the water heater is full of water.
Op
en a
hot water
f
aucet and allow a stead
y
stream o
f
water to
f
l
o
w
ou
t
of
th
e
fauce
t t
o
r
e
m
o
v
e
a
ll
a
ir
f
r
o
m th
e
h
o
t w
a
t
e
r
ci
r
cui
t.
2. With the
g
enerator runnin
g
or shore power connected
to
y
our
b
oat, sw
i
tc
h
on t
h
e
WATER
HEATER
c
i
rcu
i
t
breaker at the A
C
side o
f
the MDP.
3
. Wait
f
or the water in the tank to heat up, then use as
y
ou wou
ld
at
h
ome.
WARNING
! !
I
MPORTANT!
Water temperatures in excess 110ºF
(
43ºC
)
are
d
an
g
erous an
d
ma
y
cause sca
ldi
n
g
, severe
i
n
j
ur
y
or
d
eath
9
.4.6.1 Water Heater Temperature Ad
j
ustmen
t
(
Thermostatic Mixin
g
Valve
)
1. Let the water
f
low
f
or at least 2 minutes to allow suppl
y
temperature to stablize.
2. Calibrate the mixed water outlet temperature b
y
plac-
in
g
a thermometer in the mixed water stream
.
3
. To ad
j
ust the settin
g
o
f
the valve, loosen lockin
g
cap
with hex wrench, see fi
g
ure 9.5.0. Cap must be lifted 1/4”
to ad
j
ust temperature. To increase the temperature, tur
n
c
ounterclockwise. To decrease temperature, turn clock-
w
ise
.
4. Lower handle and ti
g
hten screw.
5
.
C
heck outlet temperature.
NOTE: Refer to Users manual in OEM Packet
.
Ho
tte
r
3
/
32
"
H
e
x
W
r
enc
h
T
u
T
T
r
n
Co
l
d
er
U
ns
c
r
e
w
,
w
li
f
t
ca
p
to
a
d
j
ust
F
i
g
ur
e
9.5.0
-
T
emperatu
T
T
re A
d
justment
T
ab
l
e
1. Scald Time
(
Hot Water
)
, References Onl
y
T
emperature Max duration until in
j
ur
y
155F
(
68.3
C)
1
seco
n
d
145F
(
62.9
C)
3
seconds
135F
(
57.2
C)
10
seconds
130F
(
54.4C
)
3
0 seconds
125F
(
51.6C
)
2 min
u
t
es
120F
(
48.8C
)
5
min
u
t
es
WARNING
! !
H
y
dro
g
en
g
as ma
y
form in water heater if not used.
Open valves. Do not smoke or use electrical appli-
a
nces for several minutes before use
.

Table of Contents