HUNTER OPERATION
c)
COMMUNICATING
( connected to a
RS232 port and
operating)
fully equipped 125mA
115mA
(208K)
(SOK)
SECTION 2. 10
As can be seen, the POWER SAVE current is very low. Although the
screen is on and the keyboard responsive to any key depression, this
is the condition in which HUNTER is expected to be most. of the time.
A typical application example might be a salesman using HUNTER for
order entry purposes at a number of customer's premises and returning
to base for communication.
2. 10.4
Exanple of Power Consumption
The day is 7.5 hours long, during which he makes five calls. At each
call he uses HUNTER for 40 minutes for stock checking and order entry
purposes. The communication time takes 15 minutes, with a further 5
minutes left powered up.
Of the 40 minutes use at each call, only 5 minutes is considered
'operation' since most of the time HUNTER is waiting for keyboard
entry.
Each Visit
Operating Power 80
X
5
=
6.67
mAH
60
Power Save Power
15
X 35
=
8.75 mAH
60
Total Visit Power
=
15.4 mAH
Total Day's Power:
5 visits at
15.4mHA
=
77 mAH
Communicating
115
X 15
=
28.75 mAH
60
Waiting aft.er corns
40
X 5
=
3,33 mAH
60
VER.V09F
PAGE 2 - 27