Englsih - 14
2�2 Quick check
Quick check is a display mode where you can
quickly see information about program versions,
battery, loop signals, sensors and operating history.
When the start page or the main menu is displayed:
Press and hold down the 0 key for ve seconds to
access the “Quick check” function.
Quick check is divided into Info and History. Info
displays current status and History displays operating
history regarding messages and search times saved.
Browse among the menus using Arrow down and
press OK to select the required function. Keep the
Arrow back button pressed in for two seconds to
leave the Quick Check function and go to the main
menu.
2�2�1 Info
Display mode General shows:
• Main program type: In this case 305.
• MSW-version: The version of the MSW
(Main Software)program (also called the
main program), e.g. 1.00.00.
• MSW Date: Date of issue of MSW, in the
format YYYY-MM-DD.
• MMI-version: The version of the MMI (Man
Machine Interface)program, e.g. 1.10.00.
• SSW-version: The version of the SSW
(Subdevice Software)program, e.g. 1.00.00.
• S/N: The mower’s serial number. This
number must correspond with the serial
number on the mower’s rating plate which is
located inside the cover.
• Production: The mower’s date of
manufacture in the format YYYY-MM-DD.
The display mode Battery shows:
• Voltage: The battery’s current voltage
level. A value of about 21V indicates a fully
charged battery and about 18V indicates a
discharged battery.
• No of chargings: The accumulated number
of charges where the battery has been fully
charged.
• Charge level: Shows the charge remaining
in the battery. When the battery is fully
charged, the charge is approximately
1200 mAh. When the charge has dropped to
approximately 300 mAh the mower returns
to the charging station.
• Current: Shows nominal regulated charge
current to and from the battery. A positive
value indicates that the battery is charging
and a negative value indicates that the
mower is using current from the battery.
• Temp: Shows current temperature in the
battery.
The display mode Loop shows:
• Signal quality: The loop signals can only be
interpreted if the value for Quality is 100%.
If the value is 99% or lower, the loop system
does not function correctly and thus neither
are the values displayed for the signals
correct.
• A-signal, front: The strength of the A-signal
measured via the front loop sensor on
the mower. The value should lie between
approximately 40 and 120 to ensure good
functionality. The closer to the loop the
mower is, the higher the value. When the
2� SPECIAL MENU FUNCTIONS
Software type: 305
MSW ver�: 1�00�00
MSW Date: 2011-01-24
MMI ver�: 1�10�00
SSW ver�: 1�00�00
Voltage: 20�1V
No of chargings: 0
Charge level: 1160 mAh
Current: -60 mA
Temp: 20�2 °C
Signal quality: 100%
A-signal, front: 80
A-signal, rear: 110
F-signal: -220
Guide-signal: 120
3020-001
3020-007
3020-007