Start/stop switch
8.4 Function check
Clean the mating surfaces and check the resistance as
follows:
Measure the resistance by connecting a multimeter to
the blue cable and the cylinder (earth). See Figure 4.
NOTE! The switch must be in the “on” position to give
the correct reading.
The resistance must not be higher than 0.5 Ω when the
switch is in the on position.
The stop switch is in the ON-position when the button is
held down and in the OFF-position the button is neutral.