EasyManua.ls Logo

Husqvarna H130 Mark II - Anti-Vibration System

Husqvarna H130 Mark II
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English - 37
Anti-vibration system
Fig. 2
Fig. 1
WARNING! The fuel used in the chainsaw
has the following hazardous properties:
1. The fluid and its fumes are poisonous.
2. Can cause skin irritation.
3. Is highly inflammable.
17 Anti-vibration system
17.1 Dismantling
1. Remove the cylinder cover, air filter, air filter holder
and clutch cover.
2. Remove the screw (A) holding the antivibration ele-
ment (B). See Figure 1.
3. Remove the antivibration element (B). See Figure 1.
4. Remove the chain catcher (C). See Figure 1.
5. Remove the antivibration element (D). See Figure 1.
6. Remove the screw (E) holding the antivibration ele-
ment (F) and. See Figure 2.
7. Remove the anti-vibration element. See Figure 2.
17.2 Cleaning and inspection
Clean and inspect all parts.
17.3 Assembly
Follow the dismantling instruction in the reverse order.
Make sure to use the correct torque. See chapter 4
Service data.
A
B
C
D
E
F

Related product manuals