OPENING THE FRONT GATE IN MANUAL AND AUTOMATIC MODE
To open the front gate during MANUAL MODE, the following steps need to be done in the following sequence:
NOTE: Before opening the front gate in MANUAL MODE, make sure that the head swing and shuttle
movements are not activated. If required, open the vise or bundling before opening the gate.
1. Open the gate.
The following will occur:
• The blade motor will stop if it is running.
• The hydraulic pump motor will stop if it is running.
• Shuttle movement will be disabled.
2. Close the gate.
3. Press the MACHINE START button.
To open the front gate during AUTOMATIC MODE, the following steps need to be done in the following
sequence:
1. Press the CYCLE PAUSE button.
2. The gate can be opened when the “GATE OPEN ENABLED” message is displayed in the upper right
corner of the operator interface panel.
The following will occur:
• The blade motor will stop if it is running.
• The hydraulic pump motor will stop if it is running.
• Shuttle movement will be disabled.
3. Close the gate to restart the cycle.
*** If the gate is closed within 25 seconds from opening, then the following message will appear
“BLADE+SERVO READY IN xx S”. Wait until it counts down to 0 and the message disappears. ***
4. Press the MACHINE START button. The hydraulic pump will start.
5. Press the CYCLE START button.
6. Press the BLADE START button. The cycle should continue from the point where it stopped.