22 ETS 3000 IO-Link
Stand: 28.04.2020 HYDAC ELECTRONIC GMBH Mat. Nr.: 669904 D
17 Technical Data
17.1 ETS 3200 with integral sensor probe
Input data
Measurement range -25 .. 100 °C (-13 .. 212 °F)
Probe length mm 18 100 250 350
Probe diameter mm 6 8 8 8
Pressure resistance bar 600 50
50 50
psi 8700 725 725 725
Mechanical connection G1/2 A ISO 1179-2
Tightening torque, recommended 45 Nm
Parts in contact with fluid Mech. conn.: Stainless steel; Seal: FKM
Output variables
Switching outputs PNP transistor switching outputs
Switching current: max. 250 mA each switch output
(ohmic resistance)
Switching cycles: > 100 million
Analogue output, permitted load
resistance
selectable: 4 .. 20 mA resistance max. 500 Ω
0 .. 10 V resistance min. 1 kΩ
Accuracy (at room temperature)
≤ ± 1.0 °C (≤ ± 2.0 °F)
Temperature drift (environment)
≤ ± 0.015 % FS / °C (≤ ± 0.0085 % FS / ° F)
Reaction time to DIN EN 60751 t
50
:
t
90
:
3 s
9 s
8 s
15 s
8 s
15 s
8 s
15 s
Repeatability
≤ ± 0.25 % FS max.
Environmental conditions
Operating temperature range -25 .. + 80 °C (-13 .. 176 °F)
(-25 .. +60 °C [ -13 .. +140 °F] für UL-Spec.)
Storage temperature range -40 .. + 80 °C (-40 .. 176 °F)
Fluid temperature range
1)
-40 .. + 100°C / -25 .. 100°C (-40 .. 212 °F/ -13 to 212°F)
- mark EN 61000-6-1 / 2 / 3 / 4
mark
2)
Certificate no.: E318391
Vibration resistance acc. to
DIN EN 60068-2-6 at 0 .. 500 Hz
≤ 10 g
Shock resistance to
DIN EN 60068-2-27 (11 ms)
≤ 50 g
Protection type to DIN EN 60529
3)
IP 67
Other data
Supply voltage
when applied acc. to UL specifications
9 .. 35 V DC, if PIN 2 = SP2
18 .. 35 V DC if PIN 2 = analogue output
– limited energy – according to 9.3 UL 61010; Class 2,
UL 1310/1585;LPS UL 60950
Residual ripple of supply voltage ≤ 5 %
Current consumption ≤ 0.535 A with active switching outputs
≤ 35 mA with inactive switching outputs
≤ 55 mA with inactive switching output
and analogue output
Display 4-digit, LED, 7 segment, red, height of digits 7 mm
Weight g 135 150 185 210
Note: Reverse polarity protection of the supply voltage, overvoltage, override and and short circuit protection
are provided.
FS (Full Scale) = relative to complete measuring range
1)
-25 °C with FPM seal, -40 °C on request
2)
Environmental conditions acc. to 1.4.2 UL 61010-1; C22.2 No. 61010-1
3)
With mounted mating connector in corresponding protection type