OperatiOn
HPR400XD Auto Gas – 806160 4-89
Aluminum
N
2
Plasma / N
2
Shield
200 A
220762220637 220307220759 220342220346
Metric
English
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
mm Volts mm mm/m mm Factor % Seconds
N
2
N
2
17 43 73 43
8
158
6.4
6000
9.0 140
0.3
10 4750 0.4
12 3500 0.5
15 166 2350 0.6
20 165 1000 0.8
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
in Volts in ipm in Factor % Seconds
N
2
N
2
17 43 73 43
5/16
158
0.25
236
0.35 140
0.3
3/8 200 0.4
1/2 120 0.5
5/8 166 80 0.6
3/4 165 50 0.8
Marking
Flow rates – lpm/scfh
N
2
Preflow 113 / 240
Cutflow 135 / 287
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps mm in mm/m ipm Volts
N
2
N
2
10 10 10 10 18 2.5 0.10 6350 250 140
Ar N
2
30 10 30 10 20 3.0 0.12 2540 100 66
220340