EasyManua.ls Logo

Hypertherm HyPerformance HPR400XD Auto Gas

Hypertherm HyPerformance HPR400XD Auto Gas
355 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance
5-52 HPR400XD Auto Gas806160
Cooler sensor board PCB2
TP8
D
1
PWR GND
TP7
+24V
TP21 TP22
+
15V–15V
+
5V
S2
CAN
SW
0
WDI
SW
1
TP18
TP6
+
3.3V
D
2
D8
D7
RX
TX
TP4
+
5V
TP23
TP1
+A
3.3V
TP16
TP10
TP3
TP17
TP15
RESET
TP2
TP9
Control PCB test points
Test point
number Description
Test point
number Description
TP1 A + 3.3 V TP12 Digital ground
TP2 Analog ground TP13 + 3.3 V
TP3 Pressure sensor (for use in the future) TP14 SCIRXD (RS422 transmit)
TP4 + 5 V TP15 Digital ground
TP6 + 3.3 V TP16 Analog ground
TP7 + 24 V TP17 Reset\
TP8 Power ground TP18 Reset
TP9 Coolant flow sensor input TP21 + 15 V
TP10 Chiller flow input (for use in the future) TP22 – 15 V
TP11 SCIRXD (RS422 receive) TP23 Line voltage input
Gas console control board LED list
LED Signal name Color
D1 + 5 VDC red
D2 + 3.3 VDC Green
D7 CAN TX
D8 CAN RX

Table of Contents