Maintenance
HPR400XD Auto Gas 806160 5-5
Sequence of operation
1. Power-up The system verifies that all of these signals are off at power-up
Coolant flow off
Chopper current off
Transfer off
Phase-loss off
Chopper 1 overtemp off
Magnetics overtemp off
Coolant overtemp off
Plasma start off
2. Purge Air or N
2
gas flows through torch for 20 seconds
Contactor closes and the chopper performs a chopper test and a current sensor test
Plasma start off
Contactor remains closed when the purge cycle ends
3. Idle
Gas pressure ok
Coolant flow on
Chopper current off
Line voltage ok
4. Preflow 2-second flow of gas
5. Pilot arc Current flows between electrode and nozzle
Chopper, main contactor and pilot arc relay are on
High frequency present
Chopper current sensor = pilot arc current
6. Transfer Pilot arc current sensed on the worklead
7. Ramp-up Chopper current increases to its setpoint and gas changes to cutflow
Coolant flow on
Gas pressure ok
Phase-loss on
Line voltage ok
8. Steady state normal operating parameters
Coolant flow on
Gas pressure ok
Phase loss on
Chopper 1 overtemp off
Magnetics overtemp off
Coolant overtemp off
9. Ramp-down Current and gas flow decrease after plasma start has been removed
Cutflow gas off
10. Auto Off 10-second postflow
Main contactors off
Choppers off