28
6.1.3 PV (solar) Power
Fig. 6.3 PV (solar )power setup
1. With all cables disconnected, press the
Battery Switch to connect the battery.
Touchscreen will light up.
2. Wait until the Bluetooth signal is ready.
Note: Bluetooth icon is highlighted blue.
3. Plug into solar power (Voc. Range 120V DC ~
500V DC, Max. Charging Power 4,400W, Max.
Input 5,000W/18A) using the included Solar
Input Breaker.
Connect all cables when Breaker is in the OFF
position. After cables are connected, flip
Breaker ON. Note: The inverter will be started
automatically.
4. Turn AC Output or DC Output on/o
as needed.
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 3 0A
PD60W
5V 2.4A
QC 3.0
PD60W
12VDC
2A
AC OUTPUT
25AMAX
AC OUTPUT M AX 15A
120VAC
PV
Home
Settings
Data
Warnings
12VDC
AC Load
DC Load
11/15/XXXX 15:15
2560 W 2560 W
2500 W
120 W 330 W
AC ON
DC OFF
INV. RESTART
100%
12V/24V
MAX
10A
·
DC INPUT
MAX
35A
·
AC INPUT
COM1
AC OUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4400W(18A)
SOLAR INPUT
ONLY CONNECT HYSOLIS 5K BATTERIES.
DO NOT USE 3RD-PARTY BATTERIES.
CONNECTING THE WRONG BATTERY
MAY DAMAGE THE UNIT AND/OR HARM
THE USER.
CAUTION!
SWITCH BATTERIES OFF
BEFORE CONNECTING OR
DISCONNECTING BATTERY
CABLES.
CAUTION!
VOLTAGE MAY BE PRESENT ON
PV INPUT WHEN INVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECT ALL INPUT AND
OUTPUT CABLES BEFORE
SWITCHING ON OR OFF.
BATTERY MAY ALWAYS BE
LEFT ON EXCEPT FOR
SHIPPING OR STORAGE.
NOTICE!
1
120VAC
PV
12VDC
AC Load
DC Load
11/15/XXXX 15:15
2560 W 2560 W
2500 W
120 W 330 W
AC ON
DC OFF
100%
ECO
Home
Settings
Information
Alerts
3
4
2
5
3