In most situations (Especially if brand new racked system and IBM Cumulus switch), you will
press Enter immediately to use VLAN tag 101.
Figure 68. Conguring VLAN tag
r. Highlight the Conrm BMC VLAN tag menu and press Enter. This conrms the VLAN tag set in the
previous option.
Figure 69. Conrming VLAN tag
s. Highlight the Run passwordless ssh check menu and press Enter. This option checks that
passowordless ssh is set up correctly.
The result must be "passwordless test is PASSED".
If the test Fails, run the next option to x.
t. Highlight the Fix passwordless ssh menu and press Enter. This xes passwordless ssh issues
that are found in the prior step.
u. Check the memory (ESS 3200).
The result is,
InspectionPassed: True
If you do not see this result, debug faulty DIMMs.
v. Check the CPU (ESS 3200).
The result is,
InspectionPassed: True
If you do not see this result, debug faulty CPUs.
w. Do not run the Check for any incorrectly formatted drives option. This option will be modied in
the future.
3. Fix VLAN IP address issue on the BMC.
Figure 70. SSR Checks for p9 EMS
Note: This applies to p9 EMS or p9 protocol node.
74
IBM Elastic Storage System 3200: Hardware Planning and Installation Guide

Table of Contents

Other manuals for IBM Elastic Storage System 3200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Elastic Storage System 3200 and is the answer not in the manual?

IBM Elastic Storage System 3200 Specifications

General IconGeneral
BrandIBM
ModelElastic Storage System 3200
CategoryStorage
LanguageEnglish

Related product manuals