Table 1. POST Error Codes (continued)
Code Description Action
1962 Boot sequence error
1. Go to Changing the primary
startup sequence on page 38
and follow the instructions to
verify that the startup sequence
is configured.
2. If the problem persists, have the
computer serviced.
2400 Display adapter failed; using
alternate.
Have the computer serviced.
2462 Video configuration error. Have the computer serviced.
5962 IDE CD-ROM configuration error Have the computer serviced.
8601 Pointing device error Have the computer serviced.
8603 Pointing device or system board
error
Have the computer serviced.
I9990301 Hard disk failure Have the computer serviced.
POST beep codes
One beep and the appearance of text on the monitor indicate successful
completion of POST. More than one beep indicates that POST detected an
error. Beep codes are sounded in a series of two or three sets of beeps.
The duration of each beep is constant, but the length of the pause between the
beeps varies. For example, a 124 beep code sounds like one beep, a pause,
two consecutive beeps, another pause, and four more consecutive beeps.
For the following beep codes, the numbers indicate the sequence and number
of beeps. For example, a 232 error symptom (a burst of two beeps, three
beeps, then two beeps) indicates a memory module problem.
If the following beep codes occur, have the computer serviced.
Beep code Probable cause
113 CMOS write/read failure
114 BIOS ROM checksum failure
121 Programmable interval timer test failure
122 DMA initialization failure
123 DMA page register write/read test failure
124 RAM refresh verification failure
131 RAM test failure
Chapter 6. Troubleshooting 77