v Yes: Continue with the next step.
v No: Go to step 25 on page 169 to process the next partition in the list you recorded in step 11 on page 168.
30. Have all the serviceable events recorded in step 4 on page 167 been processed?
v Yes: Continue with the next step.
v No: Go to step 5 on page 167 and process the next service action event in the list of serviceable events recorded in
step 4 on page 167.
31. While processing all service action events, were you directed to step 14 on page 168?
v Yes: Continue with the next step.
v No: If the system attention LED is still on, turn off the LED as described in “Activating and deactivating LEDs” on
page 154. Return the system to the customer. This completes the repair.
Note: If during the processing of the list of open service action events, some service action events remained open,
further service actions might be required to complete the repair.
32. Complete all the following steps for each entry in the list of Axx partitions you began recording in
step 14 on page 168, except for the partition you were using to debug the original problem.
33. From the list of Axx partitions, open the management console virtual terminal window of a partition
, and then type diag at the AIX command prompt.
34. When the diagnostic operating instructions are displayed, complete the following steps:
1. Press Enter.
2. Select the Task Selection option.
Note: If the terminal type is not defined, you are prompted to
define it before you can proceed.
3. Select the Log Repair option.
4. Select the resource associated with the repair action:
v If the repair action was reseating a cable or adapter, select the
resource associated with that repair action.
v If the resource associated with your repair action is not
displayed on the Resource List, select sysplanar0.
5. Click Commit after you make your selection.
35. Exit from diagnostics in this partition and return to the AIX command prompt.
36. Have all the partitions in the list of Axx partitions you began recording in step 14 on page 168 been
processed?
v Yes: Continue with the next step.
v No: Go to step 32 to process the next partition in the list you recorded in step 14 on page 168.
37. If the system attention LED is still on, turn off the LED as described in “Activating and deactivating
LEDs” on page 154. This completes the repair. Return the system to the customer.
170

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Power System POWER7 Series and is the answer not in the manual?

IBM Power System POWER7 Series Specifications

General IconGeneral
ProcessorPOWER7
L2 Cache256 KB per core
L3 Cache4 MB per core
Memory TypeDDR3
Operating SystemAIX, IBM i, Linux
VirtualizationPowerVM
Processor Cores4, 6, or 8
Form FactorRack
Release Date2010