IBM System/360 2050 - Page 108

IBM System/360 2050
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page
and
0 I 2 3 4 5 6 7 8 9
10
11
12
13
14
Test Point
Net
No.
line
Title
JOO
Nonoseconds/Oi\I
L3E7B08
GE
191
AG4
w
1
f-----
L4J4BIO
GE
191AP4
w
1
l4G2B
12
GE
191AJ4
1
r
L3f6D04
GEl91BA4
-Early
and
h
r
I---·
R.!:.fi
Reset
L3C2Dl2
'GE 191AQ4
1
J
L3C2D
10
GEl91AR4
-Ch
Reset
L3C2D04
GEl91AS4
f-------
l3F6D
I 0
GE
191AZ4
-Early
h
_f
Reset
K4h7D06
GBl71AQ4
-Trf
to
l_
~
L4L4B08
GB
171
BC4
Pas
Reg
14G4DIO
(Bl71AS4
+ Req
_J
L_
Reg
Trf
N4G7Dl2
rMICIAQ4
N4G7DIO
GMIOIAR41 t B Reg
~
l
N3H2D
12
GM
10
I
AS41
Set
N3H2DIO
GMIOIAT4
'
N4G6Dl2
f:;MI I IAY4
N4G.\DIO
pM111AZ4
+C
Reg
N3f4D
12
PMI
1 IBA4
Set
l.--I
l
N3F4D
10
GMl
1
IBB4
r--r
I I
FIGURE 100
RESET
PULSES
(CLOCK
NOT
RUNNING)
Poge
and
~t
Net
No_
L3E7B08
I
GE
l91AG4
I
l4J4BIO
GEl91AP4
f-----·
0
line
Title
w
I 2 3 4 5
6
7
100
Nanoseconds/Div
l
l
l4G2Bl2
GE191AJ4
l.__
__
__._r-1
~~~~~~t-_E--19-IB_A_4--1--;!_:'_~_:_":1_,r---i.__
_________
~_i-------l
L3C2Dl2
j~E191A04
'--------
l3C2DIO
GE
191AR4
-Ch
Reset 1
_i-------1
L3C2D04
GE
191AS4
'------'
L3F6Dl0
GE
19JAZ4
-~:~
K4H7D06 GB
171
A04
-
hf
to
L4L4B08
GBl71BC4
PosReg
L4G4D!O
GB17!AS4
N4G7D12pM10JAQ4
N4G7D!OpM101AR4
N3H2D
12icM10
IAS4
N3H2D
10
f:'Ml01AT4
+Req
Reg
hf
+ B
Reg
Set
N4G6Dl2GMI1
IAY4
N4G6010GMI1
IAZ4
+C Reg
N3F4012
GMlllBA4
Set
N3F4010
GMll1BB4
h.__
__
___.r
_[
r
FIGURE
101.
RESET
PULSES
(CLOCK
RUNNING)
l...__
__
~_r
r
L
l
A-Clock
Check
Add
jumper
from
XM4H7D04 to
ground.
1.
Set
check
switch
to
disable
position
and
rate
switch
to
process
position.
2.
Sync
scope
on L3E7B08
minus
external;
set
first
pulse
on
Figure
102 to
zero
time.
3.
Press
system
reset
to
time
pulses;
check
all
points
in
Figure
102;
ensure
that
clock
is
running.
Page
and
0
I 2 3 4 5 6 7
8
Test Point
Net
No.
line
Title
100
Nanoseconds/Div
K4C3808
GF121AA4
-Inst
Scan
h
r
K4D5010
GAIOIPB4
1 A
Clk
~
K4F7D06
GA101AN4
+ Dly
_J[_
A
Clk
K4D6004
GAlllAE4
•Clk
AO
~
K4D5B07
GAIOIAJ4
1 A
Clk
r
A Latch
K4D4D12
GAi
1 IAF4
•Clk
Al
IL.__.
K482802
CAIOIAV4
•A
Clk
I
1
B
latch
--
K4D5D06
GA:01AL4
•A
Clk
L----J----i__
__
D Latch
K4F7B
12
GAIOIBF4
-AOly
A
Clk
D
latch
K404DIO
GAlllAG4
tC1kStep
FIGURE 102. A
CLOCK
Cycle
Counter
Check
1.
Set
check
switch
to
disable
position
and
rate
switch
to
process
position.
2. Sync
scope
on
L3E7B08
plus
external;
set
first
pulse
on
Figure
103
at
zero
time.
3.
Check
all
points
in
Figure
10.3.
B-Clock
Check
1.
Set
check
switch
to
disable
position
and
rate
switch
to
process
position.
2. Sync
scope
on
L3E7B08
plus
external;
set
first
pulse
on
Figure
104
at
zero
time.
3.
Add a
temporary
jumper
between
K4M4D07
and
K4H7D10.
4.
Check
all
points
in
Figure
104.
5.
Remove
jumper
installed
in
step
3.
Tag
Generator
and Manual Stop
Controls
1.
Repeat
steps
1
and
2 of
preceding
"B
Clock
Check."
Service
Checks,
AdjW1trnent and
Removal
Procedure
(3/71)
107