8.
Remove
disk
pack No. 2 and mount
disk
pack
No.
3.
Start
disk
drive
motor
and
wait
for
the
unit
to
become
ready.
9.
Repeat
steps
2-8
as
described
under
"MS
Mode
Hardcore
(Disk)."
10.
Press
start.
11.
ROS
bit
test
records
continue
to
be
executed
until the
first
good
stop
at
location FD5.
This
word
has
bad
parity
in
group
1 and
tests
the
ROS
parity
check
circuits.
The
hard
stop
indicator
should
be
on.
12.
Press
the
force
indicator
switch. The
cur-
rent
ROS
address
should be FD5. At
this
stop,
set
the
check
control
switch
to
disable
and
press
start.
13.
SDR
indicates
a
successful
stop
as
follows:
p
p
p p
lFF
OFF
lFF
lFF
The IAR should equal
15'81
(hex).
ROS
Mode
Hardcore
(Disk):
For
error
stops
and
loops,
refer
to
the
ROS
hardcore
listing
(FLT02).
1.
Mount
disk
pack No. 4 containing
ROS
hard-
core,
zero-cycle,
and
one-cycle
tests
on a
disk
drive
attached
to a
selector
channel,
start
file
motor,
and
wait
until the
unit
becomes
ready.
2.
Select
the
unit with the load unit
rotary
switches.
3. Make
sure
the check
control
switch
is
set
to
disable.
4.
Set
the
FLT
control
switch
to
halt
after
load.
5.
Press
system
reset
with the
FLT
mode
lever
~witch
in
neutral.
6.
Place
the
FLT
mode
lever
switch in the load
position.
7.
Press
the
load pushbutton. IAR should equal
3FFC.
8.
Place
the
FLT
control
switch in
the
process
position.
9.
Press
the
start
PB.
The
IAR
should equal
490 (hex), and the fail and
binary
triggers
should be
on. The
SDR
should contain the following:
p
p p
p
lFF
OFF
lFF
lFF
10.
Place
the
FLT
control
switch in
the
process
position.
ROS
Mode Cycle
Tests
(Disk):
For
stops
not
identi-
fied in
this
section,
refer
to
the
repair
procedures.
1.
The
ROS
mode
hardcore
tests
should have
run
successfully.
2.
Press
the
start
PB.
58
(3/71)
Model
SO
FF.MM
3.
The
zero-cycle
tests
are
loaded into
storage
and
executed.
4.
Completion of the
zero-cycle
tests
automati-
cally
calls
in the
one-cycle
tests.
5. Completion of the
one-cycle
tests
results
in
a
successful
stop
with the
SDR
equal to the following:
p p p p
lFF
OFF
lFF lFF
6.
Neutralize
all
the
FLT
controls
(FLT
mode
switch
off,
FLT
control
switch
on
process,
and
check
control
switch
on
process).
7. Using the
storage
test
switches,
write
all
ones in
storage
to
restore
good
parity
to
storage.
Cycle
Test
Repair
Procedures
(Tape/Disk)
~:
The
FLT
compare
and
branch
microprogram
(QY510) cannot be
single-cycled
correctly
unless
the
FLT
mode switch
is
in the
neutral
(off)
position.
If
a
great
deal
of
trouble
is
encountered
on a
particular
test
failure,
make a note of
it
and then
continue on to the following
tests
to
attempt
to find
an
easier
failure
to
troubleshoot.
The following
procedure
may be
used
to
locate
problems
that
cause
FLT's
to
stop
before
complet-
ing
all
tests.
1.
Check the
pass/fail
triggers;
either
fail,
or
both
pass
and fail should be on.
2.
Check SDR. Byte
zero
contains hex
01
(bit 7
is
the
termination
bit).
Bits
20-31 contain the hex
value to
use
when
referring
to
Scopex.
If
bits
16-19
are
other
than
zero,
stop
is
in a
one-cycle
test.
Go
to
item
17.
If
bits
16-19
are
zero,
go
to
item
4.
3.
If
items
1 and 2
are
not
true,
check IAR.
If
IAR
is
less
than 148 (hex), the
first
six
words
of the
record
were
not executed
properly.
Refer
to
the
record
format
section.
If
IAR
is
more
than
148 (hex),
storage
location
84
will contain the
mask
address
for
the
current
test.
Note: As an aid in finding the
error,
bypass
this
test
to
see
if
there
are
multiple
errors
in the
zero-
cycle
tests.
If
no multiple
errors,
turn
back to
first
error.
4. Get Scopex
for
the
zero-cycle
tests.
5.
Find the hex value in Scopex that
agrees
with
SDR
20-31. The column following the
test
number
indicates
what the
test
was
trying
to
do with the
trigger.
R
or
O
equals
reset;
Sor
1
equals
set.
The next column contains the location of the
card
that
the failing
trigger
is
on. Change the
card.
6.
Press
start.
7.
If the
card
was
bad,
testing
continues.
Otherwise,
SDR will contain the
same
hex value
as
in
item
5.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System/360 2050 and is the answer not in the manual?

IBM System/360 2050 Specifications

General IconGeneral
BrandIBM
ModelSystem/360 2050
CategoryComputer Hardware
LanguageEnglish

Related product manuals