Page #18 background image
Error
Priority
Error
priority
is
as
follows
(highest
priority
is
1):
1.
Channel
control
check.
2.
Interface
control
check.
3.
Storage-protect
or
program
check.
4.
Chain
check.
5.
Incorrect
length
indication
(IL!).
6.
Data
check.
If
any of
these
errors
occur
simultaneously,
the
higher
priority
error
will
reset
the
lower
priority
error.
There
is
one
exception
to
this
rule.
On a
write
operation
when
the
channel
prefetches
either
an
invalid
CCW on
data
chaining
or
data
with
an
in-
valid
data
address
(storage-protect
or
program
check),
an
incorrect
length
indication
will
reset
the
storage-protect
or
program
check.
Data-check
error
is
blocked
from
setting
if
a
higher
priority
error
occurs
at
the
same
time
but
is
not
reset
if
it
is
already
on.
Diagnostic
Techniques
(3/71)
17

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System/360 2050 and is the answer not in the manual?

IBM System/360 2050 Specifications

General IconGeneral
BrandIBM
ModelSystem/360 2050
CategoryComputer Hardware
LanguageEnglish

Related product manuals