EasyManuals Logo

IBM System/360 2050 User Manual

IBM System/360 2050
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #82 background imageLoading...
Page #82 background image
Bit
A
Segment
B
Segment
C
Segment
0
Bl
L2
B3/B4
Bl
K2
B3/B4
BI
L4
B3/B4
I
Bl
L2
D5/D6
Bl
K2
05/06
Bl
L4
D5/D6
2
Bl
L2
BB/B9
Bl
K2
BB/B9
Bl
L4
B8/B9
3
B1L2
BI0/010
BlK2 BlO/DlO
Bl
L4
Bl0/010
4
BIJ2
8~4
Bl
H2
B3L'.B4
Bl
H4
B3L'.B4
5 BIJ2 D5/D6
Bl
H2
05/06
B1H4
05/06
6 BIJ2 B8/B9
BlH2 B8/B9 BlH4 B8/B9
7
BIJ2
Bl0/010
B1H2
Bl0/010
B1H4
BlO/DlO
8
Bl
G2
B3/B4
Bl
F2
B3/B4
Bl
F4
B3/B4
9
B1G2
05_&6
B1F2
0~6
B1F4
D~6
10
Bl
G2 B8/B9
Bl
F2
B8/B9
Bl
F4
B8/B9
11
B1G2
Bl0/010
BlF2
Bl0/010
BlF4 BlO/DlO
12
Bl
E2
B3/B4 BlD2 B3/B4
Bl
04
B3/B4
13
BlE2
05/06
BlD2
05/06
8104
05/06
14
Bl
E2
B8/B9 BlD2 B8/B9
B1D4
B8/B9
t---is-·
BIE2 BlO/DlO BlD2 BlO/DlO BlD4 BlO/DlO
16
Bl
B2
B3/84
A IM2 83/84
Bl
B4
B3/B4
17
Bl
B2
DS/06
AlM2
05/06
Bl
B4
DS/06
18
Bl
82
B8/B9
AlM2
88/B9
Bl
B4
B8/B9
~-
81B2
810/DlO
AIM2
810/DlO
8184
810/DlO
20
Al
L2
B3/B4
Al
K2
B3/B4
All4
B3/B4
21
Al
L2
D5/D6
Al
K2
05/06
Al
L4
05/06
22
Al
L2
B8/89
Al
K2
B8/B9
Al
L4
88/B9
23
A1L2
810/DIO
AlK2
810/010 A1L4
Bl0/010
~-
Al
H2
B3/84
Al
G2
B3/B4
A
1J4
B3/B4
25
Al
H2
DS/D6
Al
G2
D5/b6
AlJ4
D5/b6
26
A 1
H2
B8/B9
Al
G2
B8/B9
AIJ4
B8/B9
27
AlH2
810/DlO
Al
G2
810/D
10
AlJ4
BlO/DlO
28
Al
F2
B3/B4
Al
E2
B3/B4
AlG4
83/84
~---~-
AlF2
D5i'.D6
Al
E2
DSLQ6
Al
G4
DS,1J6
30
Al
F2
B8/B9
Al
E2
B8/B9
Al
G4 B8/B9
31
AlF2
810/010
AlE2 BlO/DlO
AlG4
BlO/DlO
p 0-7
AlD2
B3/B4 A1C2 83/84 A1D4
B3./B4
p 8-15
AlD2
DS/06
AlC2
DS/06
AID4D5/D6
p 16-23 A
lD2
B8/B9
AlC2
B8/B9
Al
04
B8/B9
p 24-31
AlD2
BlO/DlO
Al
C2
BlO/D
10
AlD4
BIO/DIO
FIGURE
53.
MAIN
STORAGE
TEST
POINTS
Main
Storage
Addressing
Figure
54
shows
the
inputs
and
functions
of SAR
for
both
main
and
bump
storage
addressing.
Main
Storage
Temperature
and
Humidity
The
operating
temperature
for
the
main
storage
unit
must
be
between
60°
and
90°F,
and
the
relative
humidity
must
be
between
20%
and
80%
with a
maxi-
mum
wet
bulb
temperature
of
78°F.
There
can
be
only
a
two-degree
maximum
difference
in
the
tem-
perature
between
two
arrays
of one
main
storage
unit.
Main
Storage
Power
Information
The +60
volt
XY
and
Z
supplies
are
manually
vari-
able
between
48 and
68
volts
and
are
temperature-
compensated.
Sense-
D
Segment
Gate
Pin
M9A
Amp
Final
Final
Strobe
Pin
M9
Output
Amp
In
Am~
Out
Bl
K4
B3/B4
B12
B7
B1J4
GlO
31J4
Gl2
B1K4
05/06
B13
07
B1J4
G9 BIJ4 J12
Bl
K4
B8/B9
012
G2
BIJ4 G3
B1J4
02
B1K4
Bl0/010
G4
013 BIJ4
G2
B
IJ4
J05
Bl
G4
B3/B4
Bl2
B7
B1J4
J2
Bl
J4 J4
Bl
G4
05/06
B13
07
BIJ4 013
B
IJ4
B9
Bl
G4
88/B9
012 G2
B1J4
B5
B 1 J4
B2
B1G4
BlO/DlO
G4 013
B1J4
07
B1J4D11
Bl
E4
B3/B4
Bl2
B7
BIJ4 J9 BIJ4 G13
B1E4
D~6
B13
07
B1C2
GlO
B1C2_QJ2
Bl
E4
B8/B9
012 G2
B1C2
G9
BlC2 J12
81E4
BlO/DlO G4
013
B1C2
G3 BlC2
02
B1C4
B3/B4
B12
B7
B1C2
G2
BlC2
JS
B1C4
DS;D6
B13
07
B1C2
J2
81C2
J4
B1C4
B8/B9
012
G2
B1C2
013
BIC2
B9
Bl
C4
Bl
O/D
10
G4
013
B1C2
BS
B1C2
B2
A1M4 B3/84
012
B7
B1C2
07
BIC2 DI I
AlM4
D5/D6
Bl3
07
B1C2
J9
B1C2
G13
AlM4
B8/B9 012
G2
AIJ2
GIO
AIJ2
Gl2
AIM4
Bl0/010
G4 013
AIJ2
G9
AIJ2J12
Al
K4
B3/B4
812
B7
AIJ2
G3
Al
J2
02
AlK4
05/06
B13
07
AIJ2
G2
AIJ2
J05
Al
K4
B8/B9
012 G2
AIJ2
J2
AIJ2
J4
Al
K4
Bl0/010
G4
013
AIJ2
013
AIJ2
B9
Al
H4
B3/84
Bl2
B7
A
IJ2
B5
A
1J2
B2
A1H4
D5;b6
B13
07
AIJ2
07
AIJ2Dl1
AlH4
B8/B9 012
G2
A1J2 J9
AIJ2
G13
A1H4 810/DlO
G4
013 AlE4
GlO
AlE4
G12
Al
F4
83/04
812
B7
Al
E4
G9
AlE4 J12
Al
F4
05_&_6
813
07
Al
E4
G3
Al
E4
02
Al
F4
B8/B9 012
G2
AIE4
G2
Al
E4
JS
Al
F4
Bl
0/010
G4 013
Al
E4
J2
AIE4 J4
AIC4
B:l,/84
Bl;>
87
AlE4
D13
A.!E4
89
AIC4
DS/06
Bl3
07
Al
E4
BS
Al
E4
B2
AIC4 B8/B9
012
G2
Al
E4
07
AlE4
Dl
l
AlC4
BlO/DlO G4
013 A I
E4
J9
AlE4
Gl3
Measure
de
voltages
at
the
logic
cards
under
dynamic
conditions.
All
voltages
have
a
±2%
tolerance.
Over-
Under-
voltage
voltage
TB-1
Wire
Voltage Amps
Setting
Setting
Pins
Color
~
-3.0
12.0
-4.5
1, 15
Yellow
Logic
+3.0
5.0
+4.5
2, 13 Grey
Logic
+6.0
12.0
+9.0
5.2
3,
11
Orange
Logic
+18.0
4.5
+22.0
9
White
Special
+60.
OXY
2.0
+68.0
5
Red
Tracked
+60.0Z
8.0
+68.0
7
Blue
Tracked
Upon
sensing
an
under
voltage
on the
~-
O
volt
supply,
the
unit
should
stop
cycling
within
20
milli-
seconds
and
drop
power.
Service
Checks,
Adjustment
and
Removal
Procedure
(3/71)
81

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System/360 2050 and is the answer not in the manual?

IBM System/360 2050 Specifications

General IconGeneral
BrandIBM
ModelSystem/360 2050
CategoryComputer Hardware
LanguageEnglish

Related product manuals