Page #83 background imageLoading...
Page #83 background image
•Manual
Operation---------
Addr-
Keys---------------
Address
Keys
°""'P Storage
Poths
24 25
22
23 26
27 28
29
30
31
I I
1
I I I I I I I
•ROS
Operation
--
-
Mover Latches I
CE
Field---------------Mover
Latches
Main Storoge P h
at
s
{
SAR
Co pocity
10
M~220
K~2
Storage
Addr
Register
(SAR
Storage
Addr
Bits
(SAS)
ess
)
-
ess
8
B
B
AOB
(8-31)
IAR
(8-31)
8 9
10
11
12
~ ~
~
~
~
~
00
...
N
-
8
9
10
11
12
BSM
Select
I
0
I 2 3
I
I I
T
I
IJ
13 14
15
16
17
c
J:
6
G:'
0
0
0 0
"'
8
§_
8
0
~
~
!:!,
"
"
"
"
"
"'
'°
"'
~
"'
;;:;
lQ
N
(")
-
13
14
15 16
17
-=r
14
13
12
2 3
4
5
6
7
I
I
I
T 1
I I
II
18
19
20
21
22
23 24
25
26
27
28
29
30
31
"
"
"
"
!:
N
'°
"'
N
"'
~
00
...
"'
~
~
...
N
-
"'
"'
(")
"'
N
-
18
19
20
21
22
23
24
25
26
27
28
29
30
31
11
10
9
8
7
6 5
4
3
2
1 0
I Decode Functions
R;.
)(
Y Drivers
Y Gates
x
X Gates
Only
I
Dvr
Drivers
w
Main Storage
I
L
__________
-
-~211-
sT4fiT1-
2_11
~~211-
t
I
Decode Values
4
I
I
I I
I
I
I
I
Bump
Storage Only_.....
....
s_ T
__
r:..·:.od~
~n~i~s-
_
R;.
x
8
x
X Gates
w
~vr
Gt
~1!_"
af4-r2~-
.....
_________
Decode Values
4
y
2 1
I
I I
L Drive
Line
(0
or 1 /
I I
Main or
Bump
-
L.l
__________
-LI
s::.;:~:.;;~e::.;:gc;;_t
.Al
_________________
__,l_s_yt_es___,
•These
operations bring
up
microorders
[w,
E
-A;
or
W,
E
-A
(SJ]
which tum
on
the B bit
in
SAR.
FIGURE
54.
MAIN
AND
BUMP
STORAGE
ADDRESSING
Exercise
Bump
Storage
To
exercise
the
bump
storage
portion
of
main
stor-
age,
tie
01A-BlH7B12
(SAR
B Bit)
to
ground
before
running
any
main
storage
diagnostic.
Continually
Address
One
MS
Location
To
address
a
single
main
storage
location
continually,
the
following
ROS
routine
202 (QWl
11)
may
be
used:
1. Set
IC
to
the
selected
address.
2.
Place
ROS
repeat
switch
in down position.
3. Set
data
keys
to
ROS
routine
202, and
press
start
pushbutton.
Scan
MS
for
Bad
Parity
A
simple
program
for
a full
storage
scan,
checking
for
bad
parity,
follows:
Location
0
-
00000000
Location 4
-
00000008
Location
8
-
41101004
Location c -
02041000
Location 10
-
100047FO
Location 14
-
00080000
GP-1
should
contain
hex 18
82
(3/71.) Model
SO
FEMM
This
program
will
scan
storage
to
the
error.
With the
check
switch
in the stop
position,
the
ma-
chine
will
stop
and
the
failing
address
will
be
indi-
cated
in SAR, SDR will
contain
the bad
data,
but
the
storage
location
will
have
been
changed
by
the
program.
Bit
Arrangement
of
MS
Word
A full word in
main
storage
is
arranged
as
follows:
Bits
0-7
Bits
8-15
Bits
16-23
Bits
24-31
Bit
32
Bit
33
Bit
34
Bit
35
Byte 0
Byte 1
Byte 2
Byte 3
Parity
for
byte O
Parity
for
byte 1
Parity
for
byte
2
Parity
for
byte 3
Check
Strobe
of Main
Storage
To
check
the
main
storage
strobe,
use
the following
procedure:
1.
Use
pin
B1J4J09
(ALD MC051) in the
main
storage
frame
as
the
test
point
for
strobe
A.
This
is
the
bit
eight
(segment
A
or
C)
pre-amp
output.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System/360 2050 and is the answer not in the manual?

IBM System/360 2050 Specifications

General IconGeneral
BrandIBM
ModelSystem/360 2050
CategoryComputer Hardware
LanguageEnglish

Related product manuals