EasyManuals Logo

IBM System/360 2050 User Manual

IBM System/360 2050
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #84 background imageLoading...
Page #84 background image
2. Run
the
"al~
ones"
test
and
adjust
your
scope
to
the
same
scale
as
Figure
55.
3.
Make
sure
the
strobe
falls
120 ± 10
nanosec-
onds
prior
to
the
peak
of
the
output
signal
and
then
run
a
shmoo
curve.
4.
If
the
shmoo
curve
picks
or
drops
bits
before
it
makes
the
established
limits,
re-adjust
the
5-
nanosecond
delay
tap
to
obtain
the
best
shmoo
for
both
"all
ones"
and
"all
zeros."
5.
Realize
that
if
the
strobe
is
set
near
point
b
(Figure
55)
the
tendency
is
to
pick
bits
and
if
the
strobe
is
set
near
point
c,
the
tendency
is
to
drop
bits.
6.
For
strobe
Buse
pin
B1C2J09
(ALD MC081)
as
a
test
point
and
repeat
steps
2-5.
12o:t1ons_l
d
I
Approx
I
.6v
Gnd
___
'
_____
o.
9
±_._iv
____
l~-
r
I
FIGURE
55.
MAIN
STORAGE
STROBE
Checking
MS
Drivers
and
Terminating
Diodes
Much
time
is
lost
in
machine
storage
areas
in
ob-
serving
waveforms
with a
voltage
probe.
Remember
that
a
line
with
little
or
no
current
on
it
will
appear
the
same
as
a good
line
if
you
use
a
voltage
probe.
If
you
suspect
blown
drivers
or
terminating
diodes,
use
a
current
probe.
1.
Drop
de
power
on the
machine.
2.
Locate
the
card
whose
outputs
you want to
scope
and
extend
it
with a
card
extender.
3.
On the
extender,
locate
the
line
you want
to
scope,
remove
the
short
jumper
wire
(Figure
56),
and
replace
it
with a
longer
wire.
This
will
give
you
a
sufficient
loop with which to
hang
the
current
probe.
4.
Bring
up
power
and
observe
the
pulse.
5.
Always
drop
de
power
when
changing
or
removing
driver,
or
the
jumper
wire
on
extended
drivers.
D
Pins
of
Extender
Card Plugs
;ere]
FIGURE
56.
CARD
EXTENDER
JUMPER
WIRE
Delay Line
Clock
Pins
of
Extender
Longer
Wire
for
Current
Probes
Timings
taker).
from
the
AlC6
delay
line
(Figure
57)
are
used
to
set
timing
latches.
Timings
from
the
AlF6
delay
line
are
used
to
reset
timing
latches.
Changing the
set
master
reset
timing
on the
AlC6
card
also
changes
all
timings
taken
from
the
AlF6
card
Timings
from
the
A1B6
delay
line
are
used
to
set
the
strobe
turn-ons.
+Allow
Sel
+Gate
Sel
+ Storage
Sel
~--~
MAOll
Delay
Line
Dvr
Reset
Master Request
Set Master Reset
Master
Reset
Delay
1-----l
Line
Dvr
MA021
MA031
FIGURE
57. DElAY
LINE
CLOCK
25
ns
Taps
135
SS
5
ns
Taps
Service
Checks,
Adjustment
and
Removal
Procedure
(3/71)
83

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System/360 2050 and is the answer not in the manual?

IBM System/360 2050 Specifications

General IconGeneral
BrandIBM
ModelSystem/360 2050
CategoryComputer Hardware
LanguageEnglish

Related product manuals