(V)
of
each
list
contains
the
values
which should
exist
on
these
pins
if
the
test
passes,
The
time
relative
to
the
clock
at
which
these
points should be
observed
depends on the position of
the
block within
the
logic.
The
four
classes
defined,
together
with
their
observation
times,
follow. (The clock
referred
to
is
the
clock
controlling
the output
trigger,
and
the
logic page
for
this
trigger
is
always given in
line
AA. See
Figure
39. )
1.
Group A scoping
values
must
be
measured
during
and
after
clock
time
for
the
output
trigger.
2.
Group
B
must
be
measured
during
clock
time.
3. Group C
must
be
measured
before
and
during
clock
time.
4.
Group D
must
be
measured
before
clock
time.
The
group
to
which a given
line
belongs
is
given
next
to
the
value which should be found.
Column 5 of
Figure
38 (Ref) contains a
reference
list
for
all
lines
in
the
list
starting
from
AA
(the
Columns
1
2
4
5
6
G/F
v
Pin
Net
Roi
Fed
By
....................
1C
.........................
AO
01
A-C4L4G08
RL071
A04
AA
AB
AF
Cl
01A-C4L4J06
RL071AT4
AB
Al
AC
CO
01
A-C2L5D13
BA31°1AC4
AC
AO
CO
01
A-C2G4D04
BA311
BH4
AO
AE
Al
AT
AU
BH
01
01A-C2F6G13
BA311AE4
AE
AG
Cl
01
A-C4L6803
Rl.0718D4
AG
00
01A-83K5B08
AM071AT4
RG
AH
AK
BA
01
01A-llJKSD06
AM071AS4
AH
AJ
01
exit
point) and going
through
AZ, B, and BA,
as
far
as
necessary.
Column 6
(Fed
By)
contains
the
references
of
all
sensitive
nets
feeding
the
block
to
which the
line
refers.
This
enables
the
sensitive
tree
to
be
built
up.
Because
this
is
only
the
sensitive
tree
and not
the
complete
tree,
several,
points should be noted.
The
fact
that
the output of a
block
is
sensitive
can
still
allow
either
all
or
some
of
the
inputs to be
insensitive.
Figure
40 shows
that
if
net
BA, a 1,
is
sensitive,
then
neither
of
its
inputs
is
sensitive
because
either
can
change without affecting the
out-
put. (The
FLT
concept
assumes
only a
single
fail-
ure.)
In the
case
of net CA, a 1, net
BA
is
sensi-
tive but
net
AB
is
insensitive.
Figure
40
shows
that
if
net
EA
is
sensitive,
then
neither
net
BA
nor
net
DA
is
sensitive
because
either
could change without affecting
the
output.
However, going
back
to
net
AA
we
see
that
if
this
changes,
then both inputs
to
E will change and
the
output will be affected.
Therefore,
net
AA
and both
of the inputs
to
block A
are
sensitive.
In
the
case
FLT
Sy~
I I
Cloe~
I I
Groop A
f"!
•>--+1--
j I
t \
01A-C2K4D04
KC411AC4 Al
AL
AO
DO
01
A-
83K5B02
AM071RR4
AJ
AW
BB
AS
BC
01
01A-82E3802
AN081AZ4
AK
a~.
. / Group 8 r-J
~
/GrOYpC
I
.,J
~
\
AV
AM
AN
01
01
A-C2L4807
KC4018H4
AL
G/F
DO
01A-D2F2807
DS301DC4
AM
AR
DO
01
A-D2F2B10
OS301G84
AN
AP
AQ
BE
Dl
01
A-C2K6006
KC4018J4
AO
Dl
01A-D2G3810
OS301DA4
AP
A2
01
01A-D2G3B07
DS301C84
AQ
A3
G/F
Dl
01
A-02G3809
OS301CA4
AR
A4
Dl
01A-84LSD06
BX031AJ4
AS
AX
Dl
01
A-C2G7D06
BA311
BV4
AT
01
01A-C2D2807
BA311
BT4
AU
00
01
A-D1J3802
DR0328R4
AV
AY
AZ
01
01A-8404D11
BY031AM4
AW
00
01A-84J5B13
OR0l18J4
AX
BF
01
01
A-01
J6802
OR032C84
AY
01
01
A-D1L6D09
OR032AT4
AZ
01
01A-01H5802
OR032AS4
8
A5
Dl
OlA-0106808
DR031Cl4
BA
80
01
01
A-84E3005
BY031AN4
BB
DO
01A-84C5D12
DR021
A02
BC
BG
DO
01
A-01 M6006
DR031AL4
BO
01
01A-D2F201B
DS301GA4
BE
Dl
01A-84H6007
DR011AL4
BF
DO
01A-8406D02
RK311CD4
BG
A6
01
OIA-C2G4J02
BA311AX4
BH
Al
AS
A9
BO
0
DEAD
ENTRY
Rl.071AM4
Al
ENTRY
0
01
A-D2D3804
RK231A04
A2
ENTRY
0
01
A-D2D3D06
RK231AE4
A3
ENTRY
G/F
0
01
A-D2D3803
RK231
AF4
A4
ENTRY
0 OIA-OIK7D06
RK32181'4
A5
ENTRY
1
01
A-8406!!04
RK311
BD4
A6
ENTRY
0
DEAD
ENTRY
BA311AV4
A7
ENTRY
0
DEAD
ENTRY
BA311AU4
A8
ENTRY
0
DEAD
ENTRY
BA311AT4
A9
ENTRY
0
DEAD
ENTRY
BA311
AS4
BO
ENTRY
G/F
01A-82E3
CARDS
FIGURE
38. ONE-CYCLE
TEST
DOCUMENTATION
(SCOPEX)
62
(3/71)
Model
50
FEMM
~
/
;,:;-D
•II
·
1
1
4'
_.......
~~
:""'
I NOTE,
The
clock
pulse
w;ll
be with;n 1
~)~
I
microtecond
of
the
FLT
sync:
pulse.
) )
\
'~--
~
' \
FIGURE
39. ONE-CYCLE
TEST
SCOPE
TIMINGS
c
'-----'OR
~-----1(CA)
A
c
1---'---L---1
01 0
(CA)
0
----t(OA)
FIGURE
40.
SENSITIVE
NET
EXAMPLES

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System/360 2050 and is the answer not in the manual?

IBM System/360 2050 Specifications

General IconGeneral
BrandIBM
ModelSystem/360 2050
CategoryComputer Hardware
LanguageEnglish

Related product manuals