v  Follow  the  suggested  actions  in  the  order  in  which  they  are  listed  in  the  Action  column  until  the  problem 
is  solved. 
v  See  the  Problem  Determination  and  Service  Guide  on  the  IBM  System  x  Documentation  CDto  determine  which 
components  are  customer  replaceable  units  (CRU)  and  which  components  are  field  replaceable  units 
(FRU). 
v  If  an  action  step  is  preceded  by  “(Trained  service  technician  only),”  that  step  must  be  performed  only  by  a 
trained  service  technician. 
Lit  light  path 
diagnostics  LED  with 
the  system-error  or 
information  LED  also 
lit  Description  Action 
TEMP  A  system  temperature  or  component 
has  exceeded  specifications. 
Note:  A  fan  LED  might  also  be  lit. 
1.  See  the  BMC  log  or  the  system-error  log  (see  the 
Problem  Determination  and  Service  Guide  on  the 
IBM  System  x  Documentation  CD)  for  the  source 
of  the  fault. 
2.  Make  sure  that  the  airflow  in  the  server  is  not 
blocked. 
3.  If  a  fan  LED  is  lit,  reseat  the  fan. 
4.  Replace  the  fan  for  which  the  LED  is  lit. 
5.  Make  sure  that  the  room  is  neither  too  hot  nor  too 
cold  (see  “Environment”  in  “Features  and 
specifications”  on  page  3). 
CPU  A  microprocessor  has  failed,  is 
missing,  or  has  been  incorrectly 
installed. 
Note:  (Trained  service  technician 
only)  Make  sure  that  the 
microprocessors  are  installed  in  the 
correct  sequence. 
1.  Check  the  BMC  log  or  the  system-error  log  to 
determine  the  reason  for  the  lit  LED. 
2.  Find  the  failing,  missing,  or  mismatched 
microprocessor  by  checking  the  LEDs  on  the 
system  board. 
3.  (Trained  service  technician  only)  Reseat  the  failing 
microprocessor 
4.  Replace  the  following  components  one  at  a  time, 
in  the  order  shown,  restarting  the  server  each  time: 
a.  (Trained  service  technician  only)  Failing 
microprocessor 
b.  (Trained  service  technician  only)  System  board 
S_ERR  Reserved 
VRM  A  dc-dc  regulator  has  failed  or  is 
missing. 
Note:  This  error  is  for  either  the 
VRM  or  integrated  VRD.  If  the  VRD 
has  failed,  the  system  board  must 
be  replaced  by  an  trained  service 
technician. 
1.  Check  the  BMC  log  or  the  system-error  log  to 
determine  the  reason  for  the  lit  LED  (for  a  VRM). 
2.  Find  the  failing  or  missing  VRM  by  checking  the 
LEDs  on  the  system  board. 
3.  Install  any  missing  VRMs. 
4.  Reseat  the  following  components: 
a.  Failing  VRM 
b.  (Trained  service  technician  only) 
Microprocessor  associated  with  the  VRM
5.
  Replace  the  following  components  one  at  a  time, 
in  the  order  shown,  restarting  the  server  each  time: 
a.  Failing  VRM 
b.  (Trained  service  technician  only) 
Microprocessor  associated  with  the  VRM 
c.  (Trained  service  technician  only)  System  board 
 
18  IBM  System  x3500  Type  7977:  User’s  Guide