RAID  adapter  in  the  server,  use  the  configuration  method  that  is  described  in  the 
instructions  that  come  with  that  adapter  to  view  or  change  SAS  settings  for  attached 
devices. 
See  the  ServeRAID  documentation  on  the  IBM  ServeRAID  Support  CD  for 
additional  information  about  RAID  technology  and  instructions  for  using  ServeRAID 
Manager  to  configure  your  SAS  and  RAID  controllers.  Additional  information  about 
ServeRAID  Manager  is  also  available  from  the  Help  menu.  For  information  about  a 
specific  object  in  the  ServeRAID  Manager  tree,  select  the  object  and  click  Actions→ 
Hints  and  tips. 
Configuring  the  controller 
By  running  ServeRAID  Manager  in  Startable  CD  mode,  you  can  configure  the 
controller  before  you  install  your  operating  system.  The  information  in  this  section 
assumes  that  you  are  running  ServeRAID  Manager  in  Startable  CD  mode. 
To  run  ServeRAID  Manager  in  Startable  CD  mode,  turn  on  the  server;  then,  insert 
the  CD  into  the  DVD-ROM  drive.  If  ServeRAID  Manager  detects  an  unconfigured 
controller  and  ready  drives,  the  Configuration  wizard  starts. 
In  the  Configuration  wizard,  you  can  select  express  configuration  or  custom 
configuration.  Express  configuration  automatically  configures  the  controller  by 
grouping  the  first  two  physical  drives  in  the  ServeRAID  Manager  tree  into  an  array 
and  creating  a  RAID  level-1  logical  drive.  If  you  select  custom  configuration,  you 
can  select  the  two  physical  drives  that  you  want  to  group  into  an  array  and  create  a 
hot-spare  drive. 
Using  express  configuration 
Complete  the  following  steps  to  use  express  configuration: 
1.  In  the  ServeRAID  Manager  tree,  click  the  controller. 
2.  Click  Express  configuration. 
3.  Click  Next.  The  “Configuration  summary”  window  opens. 
4.  Review  the  information  in  the  “Configuration  summary”  window.  To   change  the 
configuration,  click  Modify  arrays. 
5.  Click  Apply;  then,  click  Yes  when  asked  if  you  want  to  apply  the  new 
configuration.  The  configuration  is  saved  in  the  controller  and  in  the  physical 
drives. 
6.  Exit  from  ServeRAID  Manager  and  remove  the  CD  from  the  DVD-ROM  drive. 
7.  Restart  the  server.
Using  custom  configuration 
Complete  the  following  steps  to  use  custom  configuration: 
 
1.  In  the  ServeRAID  Manager  tree,  click  the  controller. 
 
2.  Click  Custom  configuration. 
 
3.  Click  Next.  The  “Create  arrays”  window  opens. 
 
4.  From  the  list  of  ready  drives,  select  the  two  drives  that  you  want  to  group  into 
the  array. 
 
5.  Click  the  icon  on  the  toolbar  to  add  the  selected  drives  to  the  array. 
 
6.  If  you  want  to  configure  a  hot-spare  drive,  complete  the  following  steps: 
a.  Click  the  Spares  tab. 
b.  Select  the  physical  drive  that  you  want  to  designate  as  the  hot-spare  drive, 
and  the  icon  on  the  toolbar  to  add  the  selected  drives.
 
74  IBM  System  x3500  Type  7977:  User’s  Guide