v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the Problem Determination and Service Guide on the IBM System x Documentation CDto determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Lit light path
diagnostics LED with
the system-error or
information LED also
lit Description Action
NMI A hardware error has been reported
to the operating system.
Note: The PCI or MEM LED might
also be lit.
1. See the BMC log and the system-error log (see
the Problem Determination and Service Guide on
the IBM System x Documentation CD).
2. If the PCI LED is lit, follow the instructions for that
LED.
3. If the MEM LED is lit, follow the instructions for
that LED.
4. Restart the server.
20 IBM System x3500 Type 7977: User’s Guide

Table of Contents

Other manuals for IBM x3500 - System - 7977

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3500 - System - 7977 and is the answer not in the manual?

IBM x3500 - System - 7977 Specifications

General IconGeneral
BrandIBM
Modelx3500 - System - 7977
CategoryServer
LanguageEnglish

Related product manuals