EasyManua.ls Logo

IBO BETA 2 - Troubleshooting; Utilisation

IBO BETA 2
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34
Troubleshooting
ISSUE: POSSIBLE CAUSE: SOLUTION:
The pump fails to launch
Tripped installation fuse Check the cause, replace the fuse
Overcurrent circuit breaker switched o Start the breaker
Pump damaged Replace the pump
Voltage too low
Check if the main voltage is compliant
with the supplier’s specication
Pump rotor blocked Unlock the rotor
Loud system operation
Air in the installation Vent the installation
Flow too high
Decrease the inow pressure at the
pump inlet
Loud pump operation
Air in the pump Vent it
Inow pressure too low - cavitation
Increase the inow pressure at the inlet
to the pump
Heat insuciency in the
installation
Pump parameters too low
If possible, increase the pump operation
mode into a more ecient one, otherwi-
se install stronger pump
Utilisation
The used product is subject to disposal as wastes only in selective waste
collection systems organised by the Network of Communal Electric and
Electronic Waste Collection Centres. The customer is entitled to return the
used equipment to the network of the electric equipment distributor, at
least for free and directly, if the returned device is of proper type and fulls
the same function as a newly purchased device.
It is prohibited to dispose of electric equipment together with other household waste.
The year the device was marked with the CE mark
(entered by the seller on the basis of the nameplate)

Related product manuals