3
BASIC OPERATION
3-22
Meter display selection
The transmit meter can be toggled between four func-
tions for your convenience.
Touch the Meter one or more times to select the TX
meter function, RF power meter, SWR meter, ALC
meter or COMP meter.
•Po :DisplaystherelativeRFoutputpower.
•SWR :Displays the SWR of the antenna at the fre-
quency.
•ALC :DisplaystheALClevel.Whenthemetermove-
ment shows the input signal level exceeds the
allowable level, the ALC limits the RF power.
In such cases, decrease the microphone gain
level.
•COMP:Displaysthecompressionlevelwhenthespeech
compressor is in use.
Touch the Meter for 1 second to select the Multi-
function meter.
•TouchtheMulti-functionmetertocancelthemeter.
ALC zone
Multi-function meter
When ALC meter
is selected.
RFoutputpowerisdisplayedin %(percent),
and it becomes the S-meter in receive.