BATTERY CHARGING
Rapid charging with the BC-121N+AD-106 D
The  optional  BC-121N  allows  up  to  6  battery  packs  to  be 
charged simultaneously.
Charging period: Approximately 3 hours (with BP-232H)
The following items are additionally required.
• Six AD-106 
c h a r g e r  a d a p t e r s  (purchase separately)
•  
A power adapter or the DC power cable (OPC-656)
Transceiver
Battery
pack
AD-106 charger
adapters are installed
in each slot.
Power adapter
(Purchased 
separately)
Tu rn power OFF
DC power cable (OPC-656*)
(Connect with a DC power supply; 
 13.8 V/at least 7 A)
*About the OPC-656
Red line:  Black line: 
IMPORTANT!: Battery charging caution
Ensure  the  guide  tabs  on  the  battery  pack are  correctly 
aligned  with  the  guide  rails  inside  the  charger  adapter. 
(This illustration is described with the BC-160.)
 CAUTION:
 When using the OPC-515L/OPC-656 DC power cable 
 NEVER reverse the polarity when connecting the OPC-
515L/OPC-656 to a power source. This will ruin the battery 
charger.
 OPC-515L : White line: +, Black line: _
 OPC-656  : Red line: +, Black line: _