5 - 8
ADJUSTMENT
[ADJUST ITEM]
ADJUSTMENT CONDITION OPERATION VALUE
MODULATION
BALANCE
(Narrow)
[BAL(Narrow])
1•
Channel : 1-9
No audio signals are applied to the JIG cable.
Transmitting
Connect an Oscilloscope to the
detect output terminal of the
Modulation Analyzer.
Set to the square
wave form
(Middle)*
[BAL(Mid])
2•
Channel : 1-10
Transmitting
(Wide)
[BAL(Wide])
3•
Channel : 1-11
Transmitting
*; [EUR], [EUR-01], [EUR-02] only
5-3 TRANSMIT ADJUSTMENT (continued)
Select an adjustment item using [
] / [
] keys, then set to the specifi ed value using [
] / [
] keys on the connected PC’s keyboard.
MODULATION ANALYZER
(0.1–300 MHz)
SETTING;
HPF : OFF
LPF : 20 kHz
De-emphasis : OFF
Detector : (P-P)/2
OSCILLOSCOPE
(DC to 10 kHz)
(Detect output)
ATTENUATOR
(30 dB/10 W)