EasyManua.ls Logo

Icom iC-FR5000 - Page 33

Icom iC-FR5000
181 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
(Replacement page)
Jun. 2012
• RECEIVE ADJUSTMENT
1) Select an adjustment item using cursor or [
] / [
] keys of the PC’s keyboard.
2) Set or modify the adjustment value as specifi ed using [
] / [
] keys of the PC’s keyboard, then push the [ENTER] key.
ADJUSTMENT
ADJUSTMENT CONDI-
TION
OPERATION
ADJUST-
MENT
ITEM/
POINT
VALUE
RECEIVE
SENSITIVITY
-Preparation-
1• Connect an SSG to the RX
antenna connector.
• Set the SSG as;
Level
: +20 dBµ (–87 dBm)
Modulation : 1 kHz
Deviation : 3.5 kHz
––
-Adjust- 2 • CH. : 1-27
• Receiving
1) Set the SSG as;
Frequency : 136.100 MHz
2) Select the item [BPF C ALL], then
push the [ENTER] key.
[BPF C
ALL]
(Automatic
adjustment)
S-METER
-Preparation-
NOTE: "RECEIVE SENSITIVITY" MUST be adjusted before "S-METER." When "RECEIVE SENSITIVITY" is
re-adjusted, "S-METER" MUST be re-adjusted too.
1• Connect an SSG to the RX
antenna connector.
Set the SSG as;
Frequency : 173.900 MHz
Modulation : 1 kHz
Deviation : 3.5 kHz
––
-Adjust-
(S3 level)
2 • CH. : 1-29
• Receiving
1) Set the SSG as;
Level
: +23 dBu (–84 dBm)
2) Select the item [RSSI S3 Level],
then push the [ENTER] key to store
the adjust value.
[RSSI S3
Level]
(Automatic
adjustment)
(S1 level) 3 • CH. : 1-29
• Receiving
1) Set the SSG as;
Level
: –7 dBu (–114 dBm)
2) Select the item [RSSI S1 Level],
then push the [ENTER] key, to store
the adjust value.
[RSSI S1
Level]
(Automatic
adjustment)
SQUELCH
-Preparation-
1
• Set the item [SQL Level] to "2." [SQL Level] "2"
2• Connect an SSG to the RX
antenna connector.
Set the SSG as;
Frequency : 173.900 MHz
Modulation : 1 kHz
Deviation : 3.5 kHz
Level
:
–12 dBu (–119 dBm)
––
-Adjust- 3 • CH. : 1-30
• Receiving
1)
Decrease the adjustment value
[SQL] to close the squelch once,
then increase the value to open the
squelch.
2) Select the item [SQL], then push
the [ENTER] key to store the adjust
value.
[SQL]
(Automatic
adjustment)
; The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.