TM 10-7360-226-13&P
CONTAINERIZED KITCHEN (CK) 0011 00
TROUBLESHOOTING PROCEDURES (MODERN BURNER UNIT)
0011 00-2
Table 1. Troubleshooting Procedures (Modern Burner Unit) – Continued
Malfunction Test or Inspection Corrective Action
MBU is in cook center Start right-side MBU first
MBU is in oven assembly or tray pack
heater
Check/connect fuel connection at
the base of the mechanical room
wall
Refer to TM 10-7310-281-13&P
for additional troubleshooting
guidance for the MBU
Notify unit maintenance
MBU shuts down during
operation
No power at the unit See “MBU does not start”
MBU power is on Check fuel level light on MBU.
Refuel if necessary
Refer to TM 10-7310-281-13&P
for additional troubleshooting
guidance for the MBU
Notify unit maintenance
MBU fails to fuel No power to the unit See “MBU does not start”
MBU has power but air compressor
cannot be heard
Refer to TM 10-7310-281-13&P
for additional troubleshooting
guidance for the MBU
Notify unit maintenance
MBU power is on and air compressor
is running
NOTE: Refueling can take up to
4 minutes for a single MBU, and
even longer when more than one
is refueling at a time.
Ensure that the fuel line to the fuel
can is connected, can contains
fuel, and valve on fuel can adapter
is open
Ensure that all hoses are free of
leaks and fittings are tight
Refer to TM 10-7310-281-13&P
for additional troubleshooting
guidance for the MBU
Notify unit maintenance
END OF WORK PACKAGE