TM 10-7360-226-13&P 
 
 
 
CONTAINERIZED KITCHEN (CK)  0022 00 
UNIT MAINTENANCE PROCEDURES 
 
0022 00-2 
 
perimeter of the door and by visually inspecting the entire gasket for hardness, cuts and a 
deteriorated condition.   
 
Casters:  Attempt moving the  refrigerator with the casters unlocked.  It should move freely 
without binding of the casters.  Move the refrigerator in all directions to isolate the problem to a 
particular caster.  Check for foreign material in the caster flanges.  Refer to the procedure in the 
following section to replace a caster. 
REPLACE 
Power Cord:  Make sure the power cord is unplugged from the electrical outlet.  Remove the 
screws from the access cover at the bottom rear of the refrigerator.  Unplug the connector and 
remove the green ground wire.  Install the replacement power cord and securely connect the 
green ground wire. 
 
Temperature Controller:  See Figure 1. Remove the five machine screws from the 
fan/controller panel at the inside top of the refrigerator.  Loosen the panel from the side molding 
strips being careful not to damage the trim or the wiring behind the panel.  Disconnect the 
temperature-controller connector.  Remove the mounting hardware of the temperature 
controller.  Install the replacement controller using existing hardware.  Reinstall the 
fan/controller panel and slide the side molding strips onto the edges of the panel. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 1.  Refrigerator Interior. 
 
Door Gasket:  Remove the screws from underneath the gasket material.  Align the new gasket 
around the door so that the screw holes are aligned.  Replace all hardware. 
 
TEMPERATURE 
CONTROLLER 
FAN