TM 10-7360-226-13&P
CONTAINERIZED KITCHEN (CK) 0029 00
DIRECT SUPPORT MAINTENANCE PROCEDURES
0029 00
-
1/2 Blank
TRAY PACK HEATER
THIS WORK PACKAGE COVERS:
Inspect, Repair
INITIAL SETUP
Tray Pack Heater shut down, cool, drained
Maintenance Level
Direct Support
Tools and Special Tools
Tool Kit, General Mechanic’s (WP 0052 00, Table 1, Item 1)
Shop Equipment, Welding (WP 0052 00, Table 1, Item 2)
GENERAL
This procedure contains information and instructions to keep the tray pack heater in good
working order by inspecting and repairing its metal components and subassemblies.
INSPECT
Inspect the following tray pack heater components for bent or cracked sheet metal, cracked
welds, and loose or missing rivets:
Tray pack heater
Heater base assembly
Heater fan assembly
REPAIR
Perform welding operations as described in TM 9-237, Operator’s Manual: Welding Theory and
Application.
Replace loose or missing rivets and perform sheet metal repair as described in TM 9-510, Metal
Body Repair and Related Operations.
END OF WORK PACKAGE