4-1
SECTION 4 ADJUSTMENT PROCEDURE
4-1 PREPARATION
REqUIRED EqUIPMENT ■
EqUIPMENT SPECIFICATIONS EqUIPMENT SPECIFICATIONS
Programming software
CS-M85 PROGRAMMING
SOFTWARE (Revision 1.0 or later)
Oscilloscope
Frequency range: DC~20 MHz
Measuring range: 0.01~20 V
RF power meter
(50 Ω terminated)
Measuring range: 0.1~10 W
Frequency range: 100~300 MHz
SWR: Less than 1.2 : 1
Standard signal
generator (SSG)
Frequency range: 0.1~300 MHz
Output level: −20 dBμ to 90 dBμ
(−127 to −17 dBm)
Frequency counter
Range: 0.1~300 MHz
Accuracy: ±1 ppm or better
Input level: Less than 1 mW
Audio generator (AG)
Frequency range: 300~3000 Hz
Output level: 1~500 mV
JIG cable
Modified OPC-2338 (see the
illustration on page 4-2)
Modulation Analyzer
Frequency range: 30~300 MHz
Measuring range: 0~±10 kHz
Attenuator
Attenuation: 30 dB or 40 dB
Capacity: More than 10 W
AC millivoltmeter Measuring range: 10 mV to 10 V
CONNECTIONS ■
OPC-2338
PC
Modulation
analyzer
Oscilloscope
To the antenna connector
Standard signal generator
–127 dBm to –17 dBm
(0.1 V to 32 mV)
Attenuator
30 dB or 40 dB
RF power meter
0.1~10 W/50 Ω
Frequency
counter
Loose
coupling
CAUTION!
DO NOT transmit while an
SSG is connected to the
antenna connector directly.
CAUTION!
Firmly attach to the
multi-connector, but
do not overtighten.
The tests described in this section should be measured and adjusted with the above test equipment.
However, a radio tester can also be used for these adjustment procedures.