#1 Coil Error
»
Code: E14
LED Light Display: 3 red+ 1 red
LCM Display: As shown in figure below
Cause: Coil 1 is damaged.
Corrective Measure: Notify the ICT personnel
«
#2 Coil Error
»
Code: E15
LED Light Display: 3 red + 2 red
LCM Display: As shown in figure below
Cause: Coil 2 is damaged.
Corrective Measure: Notify the ICT personnel
«
#3 Coil ERR
»
Code: E16
LED Light Display: 3 red +3 red
LCM Display: As shown in figure below
Cause: Coil 3 is damaged.
Corrective Measure: Notify the ICT personnel
«
Low Level LED Error
»
Code: E17
LED Light Display: 3 red+ 5 red
LCM Display: As shown in figure below
Cause: Low level LED is damaged. Otherwise, optical lens may be covered by dirt or
dust.
Corrective Measure: When error is detected, changer retries once a minute for 10 times. It
will stop if the problem is not resolved after 10 times retry. Clean
the optical lens with soft fabric. If the problem cannot be solved,
notify ICT personnel for support.
Coil Error #1
E14
Coil Error #2
E15
Coil Error #3
E16
Tube Detection
Sensor Error E17