Tube H/L Sensor Error
»
Code: E24
LED Light Display: 6 red+ 4 red
LCM Display: As shown in figure
Cause: Coins got stuck at the coin separation area or the coin tube opening twice in a
row, causing the HI Level Sensor to fail to detect the coin twice in a row.
Corrective Measure:
1. Open the LCM panel to verify whether coins are stuck in the coin
separation area. If yes, then push aside the transparent latch for the
coin guiding board, remove the coin guiding board, remove the stuck
coins, and then reinstall the coin guiding board. Turn on the power
again. Insert each denomination to ensure that it enters the
corresponding coin tube. If yes, then the problem has been resolved.
2. Ensure that the coin tubes have been positioned correctly.
Restart the power. Insert each denomination to ensure that it enters
the corresponding coin tube. If yes, then the problem has been
resolved.
Coin->Tube
Sensor Error E24