76
«
Tube H/L Sensor Error
A
»
Code: E25
LED Light Display: None
LCM Display: As shown in figure below
Cause: Low Level = empty, Hi Level = full. Coin might be sorted to wrong tube.
Corrective Measure: Changer retries every 2 seconds during the standby mode.
Remove the stuck coin then restart changer to solve the problem.
«
Tube H/L Sensor Error
B
»
Code: E26
LED Light Display: None
LCM Display: As shown in figure below
Cause: Low Level = empty, Hi Level = full. Coin might be sorted to wrong tube.
Corrective Measure: Changer retries every 2 seconds during the standby mode.
Remove the stuck coin then restart changer to solve the problem.
«
Tube H/L Sensor Error
C
»
Code: E27
LED Light Display: None
LCM Display: As shown in figure below
Cause: Low Level = empty, Hi Level = full. Coin might be sorted to wrong tube.
Corrective Measure: Changer retries every 2 seconds during the standby mode.
Remove the stuck coin then restart changer to solve the problem.
Tube A Sensor
Error E25
Tube B Sensor
Error E26
Tube C Sensor
Error E27