EasyManuals Logo

IDEAL 36 User Manual

IDEAL 36
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
Ultra reliable gas atmospheric boilers
High, full and part load efficiencies -
meets Building Regulations 2006 (Part L2)
Auto ignition
Remote indication kit options
CXA/H natural gas or propane CXA P/H (40-100kW)
CXA/H is On/Off and CXS/H is High/Low operation
Model 40/H 50/H 60/H 70/H 80/H 90/H 100/H 110/H 120/H
Sections 3 4 4 5 5 6 6 7 7
Output (kW) 40 50 60 70 80 90 100 110 120
Height 1000
Width 600
Depth 750 882 882 1042 1042 1212 1212 1385 1385
Flow/Return Connections (BSP)
RC2
Gas Inlet (BSP) RC
3
/4 RC
3
/4 RC
3
/4 RC
3
/4 RC
3
/4 RC1 RC1 RC1 RC1
Flue Size (mm) 150 150 175 175 200 200 200 250 250
Maximum Working Pressure (bar)
6
Water Content (L) 22 30 30 37 37 45 45 53 53
Approx Dry Weight (kg) 210 265 265 330 330 395 395 490 490
Front (mm) 750
Back (mm) 0 0 0 150 150 300 300 300 300
Sides (mm) 50 50 50 50 50 100 100 100 100
General Data Concord CXA/H S/H (40 - 120)
Option Kits
Boiler CXA/H CXS/H
Volt free contacts, boiler run,
overheat & lockout
✓✓
Down draft thermostat kit ✓✓
Header kits (available from merchants) ✓✓
Propane models
Boiler
Clearances
Concord CXA/H S/H 40 - 120kW
10
gas atmospheric

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEAL 36 and is the answer not in the manual?

IDEAL 36 Specifications

General IconGeneral
BrandIDEAL
Model36
CategoryBoiler
LanguageEnglish

Related product manuals