INsTALLATION
vogue combination boiler - Installation and Servicing
INsTALLATION
37
MENU OpERATION
INsTALLATION
VENT sysTEM
The Vent System feature aids removal of air from the heat
exchanger. The pump will be switched on for 50s and then off
for 10s while the diverter valve is moved between DHW and
CH every 30s. The feature lasts for 5 minutes.
Press ENTER and the following screen will be displayed
Press “+” and the following screen will be displayed.
Press ENTER and the following screen will be displayed.
Press ENTER and the following screen will be displayed.
The feature will end automatically after 5 minutes, to end
manually press ExIT.
pRE-hEAT
If pre-heat is switched on then the boiler will periodically re the
burner thereby reducing the time taken to provide hot water.
If pre-heat is switched off the response time will be reduced
although gas consumption will also be reduced.
Press ENTER and the following screen will be displayed
Press ENTER and a screen similar to the following will be
displayed.
To switch Pre-heat off press “-“
To switch Pre-heat on press “+”
To return to normal operation press ExIT twice.
MAxIMUM FLOW TEMpERATURE
It is possible to limit the maximum ow temperature that can
be set from the CH Flow Temperature knob using this feature.
Note that this could prevent adequate room temperature being
achieved in winter.
Press ENTER and the following screen will be displayed.
Press “-“ until the following screen is displayed.
Press ENTER and a screen similar to following will be
displayed.
Set Maximum Flow Temperature
Press “+” and “-“ until the desired temperature is displayed and
then ENTER followed by ExIT to return to normal operation.