sERVICINg
vogue combination boiler - Installation and Servicing
sERVICINg
76
DhW FILTER AND FLOW REgULATOR CLEANINg/REpLACEMENT
77
FLOW ThERMIsTOR REpLACEMENT
1. Refer to Frames 45 & 46.
2. Refer to Frame 53.
3. Isolate the DHW supply to the boiler.
4. Drain the DHW system. Refer to Frame 67.
5. Remove the DHW Flow Turbine Sensor. See Frame 71.
6. Using a spanner remove the DHW ow turbine cartridge.
7. Unscrew the ow regulator housing.
8. Remove the lter.
9. Clean or replace as necessary.
10. Ret in reverse order.
11. Open the isolating valves and rell DHW system. Refer
to Frame 67.
12. Check the operation of the boiler. Refer to Frames 33-36.
1. Refer to Frames 45 & 46.
2. Refer to Frame 53.
3. Unclip the ow thermistor.
4. Disconnect the electrical lead from the thermistor.
5. Reconnect the electrical lead to the new thermistor and
reassemble in reverse order, ensuring that the thermistor
is securely tted to the pipe on the thermistor locator tabs
as shown.
6. Check the operation of the boiler. Refer to Frames 33-36.
5
3
4
8

Other manuals for IDEAL Vogue Combi c26

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEAL Vogue Combi c26 and is the answer not in the manual?

IDEAL Vogue Combi c26 Specifications

General IconGeneral
BrandIDEAL
ModelVogue Combi c26
CategoryBoiler
LanguageEnglish

Related product manuals