IDS 1632 Installer Manual 700-256-02K Issued September 2009
20
7.6 Programming Location Summary
A detailed description of each location and its options follows.
LOCATION 0 Defaulting of the Panel or Master User Code
Value
Action
0
Will reset all locations to the factory default values.
(Master User Code 1234) and all keypad IDs will be defaulted.
1
Will default the master user code to 1234 - or 123456 if 6 digits are being used.
Master user code properties will also be defaulted.
2 Defaults ALL users
3 Defaults ALL keypads
4
Remove Missing Devices
Any missing devices (keypads, for example), will have its address freed up, making its address
available for a new device when it is enrolled. This MUST be performed when replacing a faulty
devicesee “Enrolling Keypads and Other Devices”, page 14.
7.6.1 Zone Options
LOCATIONS 1 - 32
Individual Zone Setup
Sub-location 1 Zone Type
The first sub-locations of program LOCATIONS 1 - 32 are used to define the zone characteristics of each
of the thirty two zones. There are 13 zone types. Table 3 provides a location/zone cross-reference
together with the default zone characteristics.
Table 3 : Location / Zone Defaults
Zone
Location
Sub-location 1 Default
Zone Type
1 1 1 Entry / Exit
2 2 2 Follower
3 3 4 Audible Instant
4 4 4 Audible Instant
5 5 4 Audible Instant
6 6 4 Audible Instant
7
7
4
Audible Instant
8
8
4
Audible Instant
9
9
4
Audible Instant
10 10 4 Audible Instant
11 11 4 Audible Instant
12 12 4 Audible Instant
13 13 4 Audible Instant
14 14 4 Audible Instant
15 15 4 Audible Instant
16 16 4 Audible Instant
Table continues on the next page