IDS 1632 Installer Manual 700-256-02K Issued September 2009
30
LOCATION 44 Keypad Lockout Time (Default = 30 seconds)
The value programmed into this location determines the keypad lockout period. The valid range is 0 - 255
seconds.
NOTE:
Keypad lockout is enabled by partition.
See Partition Options Page 48, Sub-location 5.
LOCATION 45 Keypad Sleep Delay
The values stored in this location work in the same way as siren delay (table on page 29). The default
value is 11, which equates to 5 minutes.
NOTE:
This function is set individually per keypad (locations 400 to 415). After this time period, if there is no
keypad activity (on this keypad) the backlighting and all other status and alarm indicators will turn off. The
power LED and if appropriate, the arm LED will remain on.
LOCATION 46 User and Installer Code Number of Digits
This location determines whether 4 or 6 digit user / installer codes are applicable. Only a value of four or
six may be programmed into this location. By default, all codes are four digits in length.
The value programmed into this location has no effect on the download code, which are always 4 digits
in length.
Code
Old four-digit code
New six-digit code
All Previously
Programmed codes
XXXX XXXX00
Installer Code
9999
999999
Master User Code 1
1234
123456
8. System Reporting Codes (4 x 2 and Domestic)
For all these locations, a two digit hexadecimal code must be programmed. To disable a reporting code
a double zero (00) must be entered into the corresponding location. Note that if one of the above
mentioned reporting digits is inadvertently omitted or programmed as a zero, the code will not be
reported. The exception to this rule is when using domestic reporting where only the first digit is used.
LOCATION 47 AC Failure Reporting Code
The control panel will transmit this code in the event of an AC failure but only after the AC failure delay
time has elapsed (See Location 39).
LOCATION 48 AC Restoral Code
The control panel will transmit this code once the AC restore delay time has elapsed. (See location 39). It
will however only be reported if an AC failure was registered as per location 47.