IDS 1632 Installer Manual 700-256-02K Issued September 2009
40
If the system is armed by means of a key-switch or non-latching remote receiver connected to
an arm/disarm zone the system will report a close by user 34.
SIA Reporting Codes
Table 11 : Standard SIA Reporting Codes
Description
Codes
Description
Codes
Close CL Siren Restore YH
Stay Close CG Battery Restore YR
Open OP Aux12v Restore YQ
Cancel OC Keypad Restore YQ
Access DG Box Tamper Restore TH
Zone Violate BA Device Restore EN
Zone Alarm Restore
BH
Bus Comms Restore
ER
Zone Bypass
BB
Prog Op Restore
YQ
Zone Force XW Dedicated Pan Rest PR
Zone Tamper BT Test Report TX
Zone Tamper Restore BJ Download RB
Zone Shutdown BB Duress HA
Zone Shutdown Restore BU KP Panic PA
AC Fail AT KP Fire FA
Comms Fail YC KP Medical MA
Line Tamper LT KP Lockout JA
Siren Fail YA Delinquency CD
Battery Low
YT
RF Jam
XQ
Aux12v Fuse
YP
RF Jam rest
XH
Keypad Fuse YP RF Sup Fail BZ
Box Tamper TA RF Pass Low Batt XT
Device Fail EM RF Pass Batt ok XR
Bus Comms Fail ET RF Rec Low Batt ET
Prog Op Fuse YP RF Rec Batt ok ER
Dedicated Pan PA Zone Exp Low Batt ET
AC Restore AR Zone Exp Batt ok ER
Comms Restore YK Fire Code FA
Line Tamper Restore LR Entry Alarm EA
Enabling / Disabling Reporting Groups
Locations 118 to 120 are used to either enable or disable the reporting of groups of reporting codes