37 before an alarm is generated. An alarm will also be generated should any single zone remain violated
for the entire delay period (Location 36). An entry/exit cannot be cross-zoned.
Swinger Shutdown
During a single arm cycle if the number of alarm violations generated by a swinger zone equals the
shutdown count (Location 33) the control panel will automatically bypass the that zone. The swinger
shutdown counter will reset when the system is disarmed and can be programmed to reset automatically
when the 24 hour self test report is generated. See Sub-location 5 of Locations 128 and 135 [Partition
Setup]
Silent Zone
This property allows any zone that would ordinarily activate the siren to be programmed as a silent zone
i.e. the violation of a silent zone while the system is armed will not activate the siren. However,
the
relevant reporting code (if programmed) will still be reported.
Zone Reporting Codes
NOTE:
For the following locations, a two digit hexadecimal code must be programmed. To disable a reporting
code a double zero (00) must be entered. If a zero is to be reported, it must be entered as hexadecimal
value A, i.e. [MODE] [0]. In the event that only 1 of the digits is programmed or an A is incorrectly
programmed as a zero the code will not be reported. If domestic reporting is used, only the first digit of
the reporting code is required / used.
Sub-location 3 Alarm Reporting Code
This is the code transmitted when the zone is violated during an arm cycle or if a panic or 24 Hour Zone
is violated.
Sub-location 4 Alarm Restoral Reporting Code
The zone restoral code is transmitted when the zone has returned to the “unviolated” condition after
triggering an alarm.
Sub-location 5 Bypass Reporting Code
A zone bypass code will be reported when a zone has been bypassed and the panel is armed.
Sub-location 6 Force Arm Reporting Code
This code will be transmitted if a partition is programmed to allow forced arming (arming with a violated
zone) and a zone is violated at the time of arming.
Sub-location 7 Tamper Reporting Code
The tamper code will be reported if tamper-by-zone has been enabled and a zone tamper occurs.