Location 18: Exit Delay Period
This is the time a person has from entering their code or using the quick arm key, [1], to exiting the
building through the entry exit zones, without setting the alarm off.
Location 19: AC Fail and Restore Time
This is the time the alarm system waits for the AC to be off or back on, before it reports back to the alarm
monitoring company. The trouble light will begin to flash immediately.
Location 20: Primary Entry Delay
The time period from opening a primary entry / exit zone to a person having to entering a valid user code,
before the alarm is triggered.
Location 21: Hardware Reset Switch Enable / Disable
If this option is enabled the alarm system cannot be defaulted via the hardware default button. The only
way to default would be via the installer code and location 0.
Note: Please make sure the installer code is changed and correct before enabling this option.