Location 142: Zone Trip Count
This and location 143 are also known as “double knock” by some. What this means is that, if a follower
zone trips this many times, while the system is armed, in the time entered into location 143.
Location 143: Zone Trip Count Time Delay
The zone must trigger the number of times set in location 142, within the time period set in this location.
Note: Value range is 0 to 15. The number entered will be multiplied by 10 to give the seconds.
Example: Location 142 has a 2 in it. Location 143 has a 3.
From the above example, time period that the violations must happen for the alarm to trigger is 3 x 10 =
30 seconds. Therefore the zone must trigger twice within 30 seconds before the system will register an
alarm.
Location 144: Trouble Display
This location is a choice of displaying a trouble condition if a fault occurs for telephone line monitoring
and a siren tamper. Both or either can be displayed.
Value
Telephone Line
Monitoring Fail
Siren
Tamper
0
No
No
1
Yes
No
2
No
Yes
3
Yes
Yes
The 805s will ignore the Telephone Line Monitoring trouble as there is no dialler.
Location 145: Trouble Display 2
Communication fail, Keypad tamper and engineer reset are the three choices.
Location 146: Keypad Sleep Delay
Choose the value that represents the time for the keypad to wait before switching all LEDs off.
Value
Communication
Fail
Keypad
Tamper
Eng.
Reset
0
No
No
No
1
Yes
No
No
2
No
Yes
No
3
Yes
Yes
No
4
No
No
Yes
5
Yes
No
Yes
6
No
Yes
Yes
7
Yes
Yes
Yes
Value
Delay
Value
Delay
Value
Delay
0
Disable
6
96sec
12
192sec
1
16sec
7
112sec
13
208sec
2
32sec
8
128sec
14
224sec
3
48sec
9
144sec
15
240sec
4
64sec
10
160sec
5
80sec
11
176sec

Other manuals for IDS 805

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDS 805 and is the answer not in the manual?

IDS 805 Specifications

General IconGeneral
Zones8
ModelIDS 805
BacklightYes
Voltage12V DC
Current50mA
DisplayLED
Operating Temperature-10°C to +50°C

Related product manuals