Location 80 to 133: Reporting Codes
These are the codes that the device at the monitoring company will turn into the corresponding action for
the operator to read and know what the incident is and react accordingly.
Note: Not required for Contact-ID. To disable a Contact-ID reporting code, enter 00 into the location
Location
Description
Location
Description
82 83
Keypad Panic
117
Bypassed Zone
84 85
Keypad Tamper
118
Zone Tamper
86 101
Zones (2 locations per
zone)
119
Zone Shutdown
102
103
AC Fail
120
Cancel
104
105
AC Restore
121
Zone Restoral
106
107
Siren Tamper
122 - 123
Download Complete
108
Away Arm
124 - 125
Telephone Line Monitoring Fail
109
Disarm
126 - 127
Telephone Line Restoral
110
Stay Arm
128 - 129
Low Battery
111 - 112
Auto Test
130 - 131
Low Battery Restoral
113 - 114
Keypad Fire
132 - 133
Box Tamper
115 - 116
Keypad Medical
Location 136 to 139: Installers Code
The default Installers code is 9999 and should always be changed once all programming is done.
Location
136
137
138
139
Value
9
9
9
9
Location 140: Swinger Shutdown Count
This is the number of times a zone must be violated while the system is armed, before it will be
automatically bypassed.
The value that is entered will be doubled. The range that can be entered is 0 to 15.
0 disables swinger shutdown.
Example: If a 5 is entered then the zone must be violated 10 times before the zone is bypassed.
Location 141: Zone Loop Response
This is the time the zone must remain violated before an alarm is registered by the system.
Value
Response
Time
Value
Response
Time
Value
Response Time
0
100ms
6
72ms
12
144ms
1
12ms
7
84ms
13
156ms
2
24ms
8
96ms
14
168ms
3
36ms
9
108ms
15
180ms
4
48ms
10
120ms
5
60ms
11
132ms