IDS X Series Training V2.3 | Partition Options
Location 211 to 218: Partition Configuration
Location Type: Bitmap
These options are to set how the system must behave when the partition needs to be armed.
Instant arm allows the alarm to arm without an exit delay
When using a zone to arm or disarm this will enable or
disable the alarm to arm without an exit delayexit delay
This is to enable/disable the pressing of the 1 key to
start the arm cycle instead of inserting a user code
This is to enable/disable the pressing of the 5 key to stay
arm
Auto Stay Arm if No Exit Zone is
Triggered
When arming with a user code and no entry/exit zone is
triggered then the alarm will automatically arm in stay
mode
Auto Stay Arm if No Exit Zone is
Triggered When Arming with a Key-
switch
When arming with a remote transmitterusing an
arm/disarm zone and no entry/exit zone is triggered then
the alarm will automatically arm in stay mode
This will bypass any triggered zone allowing the system
to be armed even though there are triggered zones
This enables or disables the ability for a user to bypass
faulty zones using the 9 key.
Arm with Zones in the Entry Route
Violated
This allows movement to take place in a follower zone
and the entry / exit zone to be violated when you are
about to arm
When the alarm arms in the away mode the siren will
give one toot to indicate that it has armed
When the alarm disarms from being away armed it will
toot twice
This will silence the keypad when the entry zone is
triggered to start the entry cycle
This will silence the keypad when the alarm starts to arm
This option will lock the alarm system, until the installers
code has been entered, when an alarm has occurred.
When enabled the alarm will automatically disarm and
the time set in locations 189
This is a global enable or disable of opening &
closing user reporting. By default all users are
enabled by default. Enabling this option and all
user codes will begin reporting opens and closes
Exercise:
Let us enable siren toot on arm and disarm so the customer will know if the alarm is armed when
using a remote transmitter.
Enter the partitions location
Option 10 and 11 need to be enabled